ASTM E 1105 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference
Hardcopy , PDF
14-07-2023
English
04-09-2015
Committee |
E 06
|
DocumentType |
Test Method
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face.
1.2This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage.
1.3This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.
1.4The proper use of this test method requires a knowledge of the principles of pressure measurement.
1.5The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.
ASTM D 7338 : 2014 | Standard Guide for Assessment Of Fungal Growth in Buildings |
ASTM E 2351 : 2004 : REV A : R2013 | Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings—Functionality (Withdrawn 2022) |
ASTM E 2112 : 2019 : REV B | Standard Practice for Installation of Exterior Windows, Doors and Skylights |
ASTM E 2266 : 2011 | Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion |
ASTM C 1401 : 2014 | Standard Guide for Structural Sealant Glazing |
ASTM E 241 : 2009 : R2014 : EDT 1 | Standard Guide for Limiting Water-Induced Damage to Buildings |
ASTM E 2112 : 2019 : REV C | Standard Practice for Installation of Exterior Windows, Doors and Skylights |
ASTM E 2128 : 2020 | Standard Guide for Evaluating Water Leakage of Building Walls |
ASTM E 241 : 2020 | Standard Guide for Limiting Water-Induced Damage to Buildings |
ASTM E 3223/E3223M : 2020 | Standard Guide for Specifying and Testing Field-Constructed Exterior Building Wall System Mockups in New Construction |
ASTM C 1401 : 2014 : R2022 | Standard Guide for Structural Sealant Glazing |
ASTM E 2266 : 2022 | Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion |
ASTM E 2128 : 2017 | Standard Guide for Evaluating Water Leakage of Building Walls |
ASTM E 2813 : 2018 | Standard Practice for Building Enclosure Commissioning |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.