ASTM E 1275 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Use of a Radiochromic Film Dosimetry System
Hardcopy , PDF
17-05-2024
English
14-10-2013
CONTAINED IN VOL. 12.02, 2001 Defines testing handling and procedure for using a radio chromic film dosimetry system to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose in water.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This is a practice for using radiochromic film dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Radiochromic film dosimetry systems are generally used as routine dosimetry systems.
1.2 The radiochromic film dosimeter is classified as a Type II dosimeter on the basis of the complex effect of influence quantities. See ASTM Practice E2628.
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for a radiochromic film dosimetry system. It is intended to be read in conjunction with ASTM E2628.
1.4 This practice covers the use of radiochromic film dosimetry systems under the following conditions:
1.4.1 The absorbed dose range is 1 Gy to 150 kGy.
1.4.2 The absorbed dose rate is 1 × 10-2 to 1 × 1013 Gy·s-1 (1-4).
1.4.3 The photon energy range is 0.1 to 50 MeV.
1.4.4 The electron energy range is 70 keV to 50 MeV.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standards | Relationship |
ISO 15556:1998 | Corresponds |
BS ISO 15557:1998 | Identical |
ISO 15557:1998 | Corresponds |
ISO 15558:1998 | Corresponds |
BS ISO 15573:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 80 keV and 300 keV |
ISO 15559:1998 | Practice for use of a radiochromic optical waveguide dosimetry system |
ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
ISO 15573:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 80 keV and 300 keV |
BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
BS ISO 15559:1998 | Practice for use of a radiochromic optical waveguide dosimetry system |
OIML R 127 : 1999 | RADIOCHROMIC FILM DOSIMETRY SYSTEM FOR IONIZING RADIATION PROCESSING OF MATERIALS AND PRODUCTS |
ASTM E 1310 : 2004 | Standard Practice for Use of a Radiochromic Optical Waveguide Dosimetry System |
BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ASTM E 1940 : 2013 | Standard Guide for Dosimetry for Sterile Insect Release Programs |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
ASTM E 1900 : 2009 | GUIDE FOR DOSIMETRY IN RADIATION RESEARCH ON FOOD AND AGRICULTURAL PRODUCTS |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
BS ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM E 1939 : 2005 | Standard Practice for Blood Irradiation Dosimetry |
ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
BS ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ISO 15562:1998 | Practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing |
BS ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
BS ISO 15562:1998 | Practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing |
ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
BS ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
BS ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ASTM E 1818 : 2013 | PRACTICE FOR DOSIMETRY IN AN ELECTRON BEAM FACILITY FOR RADIATION PROCESSING AT ENERGIES BETWEEN 80 AND 300 KEV |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ASTM E 2628 : 2009 | Standard Practice for Dosimetry for Radiation Processing |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM E 275 : 2008 | Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 275 : 2008 : R2013 | Standard Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 275 : 2008 : R2022 | Standard Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 170 : 2020 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 170 : 2023 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 958 : 2013 : REDLINE | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.