• Shopping Cart
    There are no items in your cart

ASTM E 1300 : 2016 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Determining Load Resistance of Glass in Buildings

Available format(s)

PDF

Superseded date

12-04-2024

Language(s)

English

Published date

16-08-2016

€112.17
Excluding VAT

CONTAINED IN VOL. 04.11, 2016 Specifies procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.

Committee
E 06
DocumentType
Redline
Pages
62
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This practice describes procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.

1.2This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of wind load, snow load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.

1.3This practice applies only to monolithic and laminated glass constructions of rectangular shape with continuous lateral support along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; (2) glass supported on two sides acts as a simply supported beam; and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass units with four-sided edge support.

1.4This practice does not apply to any form of wired, patterned, sandblasted, drilled, notched, or grooved glass. This practice does not apply to glass with surface or edge treatments that reduce the glass strength.

1.5This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and type of glass selected also depends upon a variety of other factors (see 5.3).

1.6Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides.

1.7The values stated in SI units are to be regarded as the standard. The values given in parentheses are for mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.8Appendix X2 lists the key variables used in calculating the mandatory type factors in Tables 1-3 and comments on their conservative values.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASCE/SEI 59 11 : 2011 BLAST PROTECTION OF BUILDINGS
ISO 28278-1:2011 Glass in building — Glass products for structural sealant glazing — Part 1: Supported and unsupported monolithic and multiple glazing
NFPA 5000 : 2018 BUILDING CONSTRUCTION AND SAFETY CODE
ASTM E 330 : 2002 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E 1233/E1233M : 2014 : REDLINE Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
ICC 2012 INTERNATIONAL BUILDING CODE : 2012 INTERNATIONAL BUILDING CODE
ACI 370R : 2014 REPORT FOR THE DESIGN OF CONCRETE STRUCTURES FOR BLAST EFFECTS
ASTM E 2461 : 2012 Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs
ASTM E 330/E330M : 2014 : REDLINE Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E 1233 : 2006 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
ICC IBC CODE AND COMMENTARY VOLUME 2 : 2015 IBC® Code and Commentary, Volume 2
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
ASTM E 330 : 2002 : R2010 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
UFC 4-010-01 : 2018 UNIFIED FACILITIES CRITERIA - DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
CSA S850 : 2012 DESIGN AND ASSESSMENT OF BUILDINGS SUBJECTED TO BLAST LOADS
ASTM E 2461 : 2012 : R2017 Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs
ASTM C 1401 : 2014 : REDLINE Standard Guide for Structural Sealant Glazing
ASTM E 997 : 2015 : REDLINE Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing
CSA A440 : 2017 NORTH AMERICAN FENESTRATION STANDARD/SPECIFICATION FOR WINDOWS, DOORS, AND SKYLIGHTS
A500-16 Building guards

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASTM D 4065 : 2012 : REDLINE Standard Practice for Plastics: Dynamic Mechanical Properties: Determination and Report of Procedures
ASTM C 1036 : 2016 : REDLINE Standard Specification for Flat Glass

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.