18-11-2013
CONTAINED IN VOL. 12.02, 2001 Describes the spectrophotometric analysis procedures for the dichromate system, and covers the preparation, testing and procedure for using the acidic aqueous silver dichromate dosimetry system to measure absorbed dose in water when exposed to ionizing radiations.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice covers the preparation, testing, and procedure for using the acidic aqueous silver dichromate dosimetry system to measure absorbed dose to water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the dichromate system. The dichromate dosimeter is classified as a type I dosimeter on the basis of the effect of influence quantities. The dichromate system may be used as either a reference standard dosimetry system or a routine dosimetry system.
1.2This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for the dichromate dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.
1.3This practice describes the spectrophotometric analysis procedures for the dichromate system.
1.4This practice applies only to gamma radiation, X-radiation/bremsstrahlung, and high energy electrons.
1.5This practice applies provided the following conditions are satisfied:
1.5.1The absorbed dose range is from 2 × 10 3 to 5 × 104 Gy.
1.5.2The absorbed dose rate does not exceed 600 Gy/pulse (12.5 pulses per second), or does not exceed an equivalent dose rate of 7.5 kGy/s from continuous sources (1).2
1.5.3For radionuclide gamma sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV.
1.5.4The irradiation temperature of the dosimeter shall be above 0°C and should be below 80°C.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 9.3.
Standards | Relationship |
ISO 15557:1998 | Corresponds |
ISO 15558:1998 | Corresponds |
ISO 15561:1998 | Identical |
ISO 15556:1998 | Corresponds |
BS ISO 15561:1998 | Identical |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
BS ISO 15563:1998 | Practice for use of the ethanol-chlorobenzene dosimetry system |
ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1276 : 2012 | PRACTICE FOR USE OF A POLYMETHYLMETHACRYLATE DOSIMETRY SYSTEM |
BS ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
ISO 15563:1998 | Practice for use of the ethanol-chlorobenzene dosimetry system |
ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ASTM E 1538 : 2009 | PRACTICE FOR USE OF THE ETHANOL-CHLOROBENZENE DOSIMETRY SYSTEM |
BS ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ISO 15555:1998 | Practice for use of a ceric-cerous sulfate dosimetry system |
ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
BS ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
BS ISO 15555:1998 | Practice for use of a ceric-cerous sulfate dosimetry system |
BS ISO 15558:1998 | Practice for use of a polymethylmethacrylate dosimetry system |
BS ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
BS ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ASTM E 1540 : 2004 | PRACTICE FOR USE OF A RADIOCHROMIC LIQUID DOSIMETRY SYSTEM |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 925 : 2009 : R2022 | Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidth does not Exceed 2 nm |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM E 958 : 2013 : R2021 | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |
ASTM C 912 : 2017 : REDLINE | Standard Practice for Designing a Process for Cleaning Technical Glasses |
ASTM E 178 : 2016 : REV A | Standard Practice for Dealing With Outlying Observations |
ASTM E 275 : 2008 | Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 275 : 2008 : R2013 | Standard Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 275 : 2008 : R2022 | Standard Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 170 : 2020 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 178 : 2021 | Standard Practice for Dealing With Outlying Observations |
ASTM E 925 : 2009 : R2014 | Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidth does not Exceed 2 nm |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 178 : 2000 | Standard Practice for Dealing With Outlying Observations |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 666 : 2021 | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 170 : 2023 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 178 : 1994 | Standard Practice for Dealing With Outlying Observations |
ASTM E 958 : 2013 | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 666 : 2014 | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 958 : 2013 : REDLINE | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.