ASTM E 1538 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
PRACTICE FOR USE OF THE ETHANOL-CHLOROBENZENE DOSIMETRY SYSTEM
Hardcopy , PDF
15-03-2002
English
01-01-2009
CONTAINED IN VOL. 12.02, 2001 Establishes the preparation, handling, testing, and procedure for the use of ethanol-chlorobenzene dosimetry system to measure absorbed dose in materials irradiated by photons and electrons in terms of absorbed dose in water. Defines the titration analysis as a standard readout procedure for the ECB dosimeter. Applies only to gamma rays, X rays, and high-energy electrons.
Committee |
E 10
|
DocumentType |
Standard
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
Standards | Relationship |
ISO 15563:1998 | Corresponds |
BS ISO 15563:1998 | Identical |
ISO 15556:1998 | Corresponds |
BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
BS ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM E 1939 : 2005 | Standard Practice for Blood Irradiation Dosimetry |
ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
BS ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
BS ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ASTM E 1940 : 2013 | Standard Guide for Dosimetry for Sterile Insect Release Programs |
BS ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM D 941 : 1988 | Test Method for Density and Relative Density (Specific Gravity) of Liquids by Lipkin Bicapillary Pycnometer (Withdrawn 1993) |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM C 912 : 2017 : REDLINE | Standard Practice for Designing a Process for Cleaning Technical Glasses |
ASTM E 275 : 2008 | Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 1401 : 2013 | Standard Practice for Use of a Dichromate Dosimetry System |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ISO 11137:1995 | Sterilization of health care products Requirements for validation and routine control Radiation sterilization |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
ASTM E 958 : 2013 : REDLINE | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |