ASTM E 2067 : 2015 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
13-11-2015
English
01-11-2015
CONTAINED IN VOL. 04.07, 2015 Defines methods to construct, calibrate, and use full scale oxygen consumption calorimeters to help minimize testing result discrepancies between laboratories.
Committee |
E 05
|
DocumentType |
Redline
|
Pages |
30
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice deals with methods to construct, calibrate, and use full scale oxygen consumption calorimeters to help minimize testing result discrepancies between laboratories.
1.2The methodology described herein is used in a number of ASTM test methods, in a variety of unstandardized test methods, and for research purposes. This practice will facilitate coordination of generic requirements, which are not specific to the item under test.
1.3The principal fire-test-response characteristics obtained from the test methods using this technique are those associated with heat release from the specimens tested, as a function of time. Other fire-test-response characteristics also are determined.
1.4This practice is intended to apply to the conduction of different types of tests, including both some in which the objective is to assess the comparative fire performance of products releasing low amounts of heat or smoke and some in which the objective is to assess whether flashover will occur.
1.5This practice does not provide pass/fail criteria that can be used as a regulatory tool, nor does it describe a test method for any material or product.
1.6For use of the SI system of units in referee decisions, see IEEE/ASTM SI-10,. The units given in parentheses are provided for information only.
1.7This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
Note 1:This is the standard caveat described in section F2.2.2.1 of the Form and Style for ASTM Standards manual for fire-test-response standards. In actual fact, this practice does not provide quantitative measures.
1.8Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests. Fire testing involves hazardous materials, operations, and equipment. See also Section 7.
1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2632/E2632M : 2013 : EDT 1 | Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials |
ASTM E 1537 : 2016 : REDLINE | Standard Test Method for Fire Testing of Upholstered Furniture |
NFPA 556 : 2016 | GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES |
NFPA 555 : 2017 | METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER |
NFPA 400 : 2016 | HAZARDOUS MATERIALS CODE |
NFPA 556 : 2020 | GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES |
NFPA 921 : 2017 | GUIDE FOR FIRE AND EXPLOSION INVESTIGATIONS |
ASTM E 2632/E2632M : 2013 | Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials |
ASTM E 603 : 2017 : REDLINE | Standard Guide for Room Fire Experiments |
ASTM E 2257 : 2017 : REDLINE | Standard Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies |
NFPA 289 : 2013 | STANDARD METHOD OF FIRE TEST FOR INDIVIDUAL FUEL PACKAGES |
ASTM E 1590 : 2017 : REDLINE | Standard Test Method for Fire Testing of Mattresses |
ASTM E 2574/E2574M : 2017 : REDLINE | Standard Test Method for Fire Testing of School Bus Seat Assemblies |
ASTM E 2280 : 2017 : REDLINE | Standard Guide for Fire Hazard Assessment of the Effect of Upholstered Seating Furniture Within Patient Rooms of Health Care Facilities |
ASTM E 3082 : 2017 | Standard Test Methods for Determining the Effectiveness of Fire Retardant Treatments for Natural Christmas Trees |
ASTM E 603 : 2017 : REDLINE | Standard Guide for Room Fire Experiments |
UL 1685:4ED 2015-07-07 | Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables |
ASTM E 1537 : 2016 : REDLINE | Standard Test Method for Fire Testing of Upholstered Furniture |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
ASTM D 6113 : 2016 : REDLINE | Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables |
NFPA 267 : 1998 | METHOD OF TEST FOR FIRE CHARACTERISTICS OF MATTRESSES AND BEDDING ASSEMBLIES EXPOSED TO FLAMING IGNITION SOURCE |
ISO 13943:2017 | Fire safety — Vocabulary |
ASTM E 906 : 2009 | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method |
NFPA 289 : 2013 | STANDARD METHOD OF FIRE TEST FOR INDIVIDUAL FUEL PACKAGES |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
ASTM E 1740 : 2015 : REDLINE | Standard Test Method for Determining the Heat Release Rate and Other<brk/> Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone Calorimeter |
UL 1975:3ED 2006-11-27 | Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes |
ASTM E 1474 : 2014 : REDLINE | Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter |
NFPA 265 : 2015 | METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS |
NFPA 286 : 2015 | STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH |
ASTM E 1590 : 2017 : REDLINE | Standard Test Method for Fire Testing of Mattresses |
NFPA 266 : 1998 | METHOD OF TEST FOR FIRE CHARACTERISTICS OF UPHOLSTERED FURNITURE EXPOSED TO FLAMING IGNITION SOURCE |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
ASTM E 1623 : 2016 : REDLINE | Standard Test Method for Determination of Fire and Thermal Parameters of Materials, Products, and Systems Using an Intermediate Scale Calorimeter (ICAL) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.