ASTM F 1710 : 2008 : R2016
Current
The latest, up-to-date edition.
Standard Test Method for Trace Metallic Impurities in Electronic Grade Titanium by High Mass-Resolution Glow Discharge Mass Spectrometer (Withdrawn 2023)
Hardcopy , PDF
English
16-05-2016
CONTAINED IN VOL. 10.04, 2016 Defines the determination of concentrations of trace metallic impurities in high purity titanium.
Committee |
F 01
|
DocumentType |
Test Method
|
Pages |
6
|
ProductNote |
Reconfirmed 2016
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This test method covers the determination of concentrations of trace metallic impurities in high purity titanium.
1.2This test method pertains to analysis by magnetic-sector glow discharge mass spectrometer (GDMS).
1.3The titanium matrix must be 99.9 weight % (3N-grade) pure, or purer, with respect to metallic impurities. There must be no major alloy constituent, for example, aluminum or iron, greater than 1000 weight ppm in concentration.
1.4This test method does not include all the information needed to complete GDMS analyses. Sophisticated computer-controlled laboratory equipment skillfully used by an experienced operator is required to achieve the required sensitivity. This test method does cover the particular factors (for example, specimen preparation, setting of relative sensitivity factors, determination of sensitivity limits, etc.) known by the responsible technical committee to effect the reliability of high purity titanium analyses.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 3166 : 2016 | Standard Specification for High-Purity Titanium Sputtering Target Used for Through-Silicon Vias (TSV) Metallization (Withdrawn 2023) |
ASTM F 2063 : 2018 | Standard Specification for Wrought Nickel-Titanium Shape Memory Alloys for Medical Devices and Surgical Implants |
ASTM E 1257 : 2016 | Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis |
ASTM E 135 : 2023 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2021 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 1257 : 1993 : R1998 : EDT 1 | Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis |
ASTM E 691 : 2020 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2019 : EDT 1 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 135 : 2003 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 691 : 2023 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 135 : 2023 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 180 : 2003 | Standard Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals (Withdrawn 2009) |
ASTM E 691 : 2022 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2009 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 135 : 2002 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2022 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 1257 : 1993 : R2003 | Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis |
ASTM E 691 : 2021 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 135 : 2022 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2021 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2003 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2003 : REV C | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 173 : 1993 | Practice for Conducting Interlaboratory Studies of Methods for Chemical Analysis of Metals (Withdrawn 1997) |
ASTM E 135 : 2022 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 1257 : 1993 : R2008 | Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis |
ASTM E 135 : 2020 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 1257 : 2016 : REDLINE | Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.