Specification for electrically driven refrigerant condensing units
Hardcopy , PDF
01-10-2005
English
31-08-1990
Committees responsible
Foreword
Specification
1 Scope
2 Definitions
3 Design and construction
4 Testing
5 Documentation and marking
Appendix
A Type testing of condensing units and their components
Table
1 Conditions for the maximum continuous current test
Figure
1 Supply circuit for locked rotor test of a motor-
compressor of the single-phase type
Requirements for the design, construction and testing of units up to a power input of approximately 25 kW.
Committee |
RHE/17
|
DevelopmentNote |
Supersedes BS 1608(1966) & 88/70358 DC. (06/2004)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
ASME PV CODE 8 DIV 2 : 2017 | BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 2- ALTERNATIVE RULES |
BS 5420:1977 | Specification for degrees of protection of enclosures of switchgear and controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. |
BS 3170:1972 | Specification for flexible couplings for power transmission |
UL 207:8ED 2009-04-20 | Standard for Refrigerant-Containing Components and Accessories, Nonelectrical |
ASME PV CODE 8 DIV 1 : 2017 | BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 1 |
BS 5267:1976 | Specification. Capacitors for single phase a.c. motors |
BS 3456-201:1990 | Specification for safety of household and similar electrical appliances General requirements |
BS 4999-111:1987 | General requirements for rotating electrical machines Specification for built-in thermal protection for electric motors rated at 660 volts a.c. and below |
BS 1586:1982 | Methods for performance testing and presentation of performance data for refrigerant condensing units |
BS 5304:1988 | Code of practice for safety of machinery |
BS 5000-11(1973) : 1973 | SPECIFICATION FOR ROTATING ELECTRICAL MACHINES OF PARTICULAR TYPES OR FOR PARTICULAR APPLICATIONS - PART 11: SMALL-POWER ELECTRIC MOTORS AND GENERATORS |
BS 5419:1977 | Specification for air-break switches, air-break disconnectors, air-break switch disconnectors and fuse-combination units for voltages up to and including 1000 V a.c. and 1200 V d.c. |
IEC 60335-2-34:2012+AMD1:2015+AMD2:2016 CSV | Household and similar electrical appliances - Safety - Part 2-34:Particular requirements for motor-compressors |
BS 1723:1963 | Specification for brazing |
BS 2871-2:1972 | Specification for copper and copper alloys. Tubes Tubes for general purposes |
BS 7005:1988 | Specification for design and manufacture of carbon steel unfired pressure vessels for use in vapour compression refrigeration systems |
BS 5424-1:1977 | Specification for controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. Contactors |
BS 4434:1995 | Specification for safety and environmental aspects in the design, construction and installation of refrigerating appliances and systems |
BS 5643:1984 | Glossary of refrigeration, heating, ventilating and air-conditioning terms |
BS 4941-1:1979 | Specification for motor starters for voltages up to and including 1000 V a.c. and 1200 V d.c. Direct-on-line (full voltage) a.c. starters |
BS 4999-101:1987 | General requirements for rotating electrical machines Specification for rating and performance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.