BS 5424-3:1988
Current
The latest, up-to-date edition.
Specification for controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. Additional requirements for contactors subject to certification
Hardcopy , PDF
English
29-02-1988
National foreword
Committees responsible
1 General
2 Definitions
3 Classification
4 Characteristics of contactors
5 Nameplates
6 Standard conditions for operation in service
7 Standard conditions for construction
8 Tests
Appendices
A Information to be given by the user when conditions
for operation in service differ from the standard
B Clearances and creepage distances for low-voltage
contactors
C Protection of a contactor by a short-circuit
protective device
D Conventional test circuit for verification of making
and breaking capacities for categories AC-1 to AC-4
and DC-1 to DC-5
AA Impact test apparatus
BB Test series to be carried out and number of samples
to be submitted for certification purposes
Deals with electro-magnetic air break contactors in accordance with I E C Publication 158-1 for which additional requirements are necessary to specify in enough detail certain testing characteristics and procedures. Included are sections on definitions, classification, characteristics of contactors, nameplates, standard conditions for operation in service and construction, and tests.
Committee |
PEL/121/1
|
DevelopmentNote |
Supersedes 76/26979 DC & 89/30585 DC. Also numbered as IEC 60158-3. (08/2005)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
First paragraph
Replacement:
This standard applies to electro-magnetic air-break contactors in accordance with IEC Publication 158-1 for which additional requirements are necessary in order to specify in sufficient detail certain testing parameters and procedures.
Additional notes:
— The need for additional requirements appears, for example, when contactors have to be tested and certified by appropriate testing authorities because of national or other laws or rules.
— If control switches are incorporated in contactors they shall comply with I EC Publication 337-1: Control Switches (Low-voltage Switching Devices for Control and Auxiliary Circuits, Including Contactor Relays), Part 1: General Requirements.
BS 7354:1990 | Code of practice for design of high-voltage open-terminal stations |
BS EN 60255-6:1995 | Electrical relays Measuring relays and protection equipment |
BS 5420:1977 | Specification for degrees of protection of enclosures of switchgear and controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. |
BS 6458-2.1:1984 | Fire hazard testing for electrotechnical products. Test methods Glow-wire test |
IEC 60158-1C:1982 | Third supplement |
BS 5424-1:1977 | Specification for controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. Contactors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.