BS 5925:1991
Current
The latest, up-to-date edition.
Code of practice for ventilation principles and designing for natural ventilation
Hardcopy , PDF
English
31-05-1991
Committees responsible
Foreword
Section 1. General
1 Scope
2 Definitions
3 Symbols
Section 2. General principles of ventilation
4 Basic data
5 Application
6 Provision for ventilation
7 Choice between natural and mechanical ventilation
Section 3. Natural ventilation
8 General
9 Flow characteristics of openings
10 Generation of pressure differences
11 Meteorological variables
12 Determination of natural ventilation rates
13 Other mechanisms of natural ventilation
14 Fire ventilation
15 Air infiltration
16 Normal building practice for natural ventilation in
dwellings
Appendix A - Bibliography
Appendix B - Calculation of contaminant concentration
Appendix C - Calculation of ventilation rates to reduce
the risk of surface condensation under steady
state conditions
Appendix D - Determination of ventilation requirements
Appendix E - Calculation of reference wind speed ur
Appendix F - Calculation of natural ventilation rates for a
simple building
Index
Publication(s) referred to
Recommendations for designing for the natural ventilation of buildings for human occupation. Reasons for the provision of ventilation and, where possible, recommends quantitative air flow rates. The basis for the choice between natural and mechanical ventilation and guidance on the design of natural ventilation systems.
Committee |
B/540
|
DevelopmentNote |
Supersedes 89/17211 DC and BS 5925(1980) (09/2005) Reviewed and Confirmed by BSI, August 2007. (07/2007)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard gives recommendations on the principles which should be observed when designing for the natural ventilation of buildings for human occupation. The standard is in three sections, as follows: Section1. General Section2 outlines the main reasons for the provision of ventilation and, where possible, recommends quantitative air flow rates. It is shown that these form the basis for air supply recommendations for different types of buildings and rooms characterized by usage. The basis for the choice between natural and mechanical ventilation is given. The design of mechanical ventilation systems is dealt with in BS5720. Section3 gives recommendations on the design of natural ventilation systems and on the estimation of air infiltration rates in housing. AppendixA is a bibliography and reference to publications listed in it are shown as: (see AppendixA [15]). AppendixB gives recommendations on evaluating contamination risks. AppendixC gives recommendations on calculating ventilation rates to reduce the risk of surface condensation under steady state conditions. AppendixD gives recommendations on determining ventilation requirements. AppendixE gives recommendations on calculating reference wind speed. AppendixF gives recommendations on calculating natural ventilation rates for a simple building. This standard does not attempt to address thermal comfort aspects of ventilation such as indoor air movement, temperature stratification, exact position of ventilation openings etc. NOTE The titles of the publications referred to in this standard are listed on the inside back cover.
BS 8211-1:1988 | Energy efficiency in housing Code of practice for energy efficient refurbishment of housing |
BS 6896:2005 | Specification for installation of gas-fired overhead radiant heaters for industrial and commercial heating (2nd and 3rd family gases) |
BS 7083:1996 | Guide to the accommodation and operating environment for information technology (IT) equipment |
BS 6230:2011 | Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases) |
BS 6230:1991 | Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd family gases) |
BS 6465-1(2006) : 2006 | SANITARY INSTALLATIONS - PART 1: CODE OF PRACTICE FOR THE DESIGN OF SANITARY FACILITIES AND SCALES OF PROVISION OF SANITARY AND ASSOCIATED APPLIANCES |
BS EN 60079-10-1:2015 | Explosive atmospheres Classification of areas. Explosive gas atmospheres |
PD CEN/TR 14788:2006 | Ventilation for buildings. Design and dimensioning of residential ventilation systems |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
BS 7967-5:2010 | Carbon monoxide in dwellings and other premises and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in non-domestic premises for the measurement of carbon monoxide and carbon dioxide levels and the determination of combustion performance |
CEN/TR 14788:2006 | Ventilation for buildings - Design and dimensioning of residential ventilation systems |
BS 6230:2005 | Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases) |
BS 5250(2011) : 2011 | CODE OF PRACTICE FOR CONTROL OF CONDENSATION IN BUILDINGS |
BS 6173:2001 | Specification for installation of gas-fired catering appliances for use in all types of catering establishments (2nd and 3rd family gases) |
BS 6173:2009 | Specification for installation and maintenance of gas-fired catering appliances for use in all types of catering establishments (2nd and 3rd family gases) |
PD IEC/TR 61831:2011 | On-line analyser systems. Guide to design and installation |
UNE-EN 60079-10-1:2016 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
BS 7880:1997 | Code of practice for draught control of existing doors and windows in housing using draughtstrips |
BS 8409:2009 | Fully enclosed play facilities. Code of practice |
BS 8485:2007 | Code of practice for the characterization and remediation from ground gas in affected developments |
IEC TR 61831:2011 | On-line analyser systems - Guide to design and installation |
BS 8409:2002 | Soft indoor play areas. Code of practice |
BS 8485:2015 | Code of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings |
EEMUA 138 : 2010 | DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS |
BS 6465-1:1994 | Sanitary installations Code of practice for scale of provision, selection and installation of sanitary appliances |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS IEC 61831:1999 | On-line analyser systems. Guide to design and installation |
BS 6229:2003 | Flat roofs with continuously supported coverings. Code of practice |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
I.S. EN 60079-10-1:2015 | EXPLOSIVE ATMOSPHERES - PART 10-1: CLASSIFICATION OF AREAS - EXPLOSIVE GAS ATMOSPHERES |
BS 5410-2:2013 | Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services |
BS 8207:1985 | Code of practice for energy efficiency in buildings |
BS 8303:1986 | Code of practice for installation of domestic heating and cooking appliances burning solid mineral fuels |
BS 5720:1979 | Code of practice for mechanical ventilation and air conditioning in buildings |
BS 5643:1984 | Glossary of refrigeration, heating, ventilating and air-conditioning terms |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.