BS 7535:1992
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Guide to the use of electrical apparatus complying with BS 5501 or BS 6941 in the presence of combustible dusts
Hardcopy , PDF
01-08-2007
English
15-08-1992
Committees responsible
Foreword
Guide
Section 1. General
1.1 Scope
1.2 Definitions
1.3 Classification of hazardous areas
1.4 Properties of combustible dusts
1.5 Other hazards
Section 2. Principles for selection of apparatus and
systems
2.1 General
2.1.1 Selection according to apparatus construction
2.1.2 Selection according to surface temperature
2.1.3 Selection for use within the dust containment
2.2 Selection of apparatus complying with BS 5501 :
Part 2 (oil immersion 'o')
2.3 Selection of apparatus complying with BS 5501 :
Part 3 (pressurized apparatus 'p')
2.4 Selection of apparatus complying with BS 5501 :
Part 4 (powder filling 'q')
2.5 Selection of apparatus complying with BS 5501 :
Part 5 (flameproof enclosure 'd')
2.6 Selection of apparatus complying with BS 5501 :
Part 6 (increased safety 'e')
2.7 Selection of apparatus and systems in accordance
with BS 5501 Part 7 and 9 respectively
(intrinsically safe apparatus and systems 'i')
2.8 Selection of apparatus complying with BS 5501 :
Part 8 (encapsulation 'm')
2.9 Selection of apparatus complying with BS 6941
(with type of protection N)
Section 3. Installation of apparatus and systems
3.1 General
3.2 Installation of apparatus complying with
BS 5501 : Part 2 (oil immersion 'o')
3.3 Installation of apparatus complying with
BS 5501 : Part 3 (pressurized apparatus 'p')
3.4 Installation of apparatus complying with
BS 5501 : Part 4 (powder filling 'q')
3.5 Installation of apparatus complying with
BS 5501 : Part 5 (flameproof enclosure 'd')
3.6 Installation of apparatus complying with
BS 5501 : Part 6 (increased safety 'e')
3.7 Installation of apparatus and systems complying
with BS 5501 : Parts 7 and 9 respectively
(intrinsically safe apparatus and systems 'i')
3.8 Installation of apparatus complying with
BS 5501 : Part 8 (encapsulation 'm')
3.9 Installation of apparatus complying with BS 6941
(with type of protection 'N')
Section 4. Inspection, testing and maintenance of
apparatus and installations
4.1 General
4.2 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 2 (oil immersion
'o')
4.3 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 3 (pressurized
apparatus 'p')
4.4 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 4 (powder filling
'q')
4.5 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 5 (flameproof
enclosure 'd')
4.6 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 6 (increased safety
'e')
4.7 Inspection, testing and maintenance of apparatus
and systems complying with BS 5501 : Parts 7 and
9 respectively (intrinsically safe apparatus
and systems 'i')
4.8 Inspection, testing and maintenance of apparatus
complying with BS 5501 : Part 8 (encapsulation
'm')
4.9 Inspection, testing and maintenance of apparatus
complying with BS 6941 (with type of protection
N)
Tables
1 Ip rating requirements and impact strength of
apparatus complying with BS 5501 and BS 6941
2 Minimum action on pressure failure
3 Minimum conductor sizes
4 Minimum clearances
5 Characteristics to be met and failures to be
taken into consideration for individual cable
types
6 Inspection schedule for all apparatus
7 Additional inspection schedule for apparatus
with additional protection
8 Class of insulating material and limiting
temperature
Figures
1 Identification of zones on drawings
2 Minimum tE time for motors in relation to IA/IN
3 Self-contained apparatus (F.2): paging system
4 Simple apparatus (F.3.4): thermocouple with
direct deflection indicator
5 Certified associated apparatus
6 Certified apparatus (F.3.2) with compatible
parameters
7 Other combinations of certified apparatus for
solenoid valve: barrier
8 Certified systems for microphone and loudspeaker
system
9 Typical procedural stages for intrinsically safe
installations
10 Conventional limit switch installation
11 Conventional level switch installation
12 Limit switches in common multicore possibly
subject to mechanical damage (type A cable)
13 Limit switches connected via a multicore
adequately supported and protected (type B cable)
14 Limit switch and float switch in individually
screened circuits bonded at different points
(type A or B cable)
15 Different circuits within an overall screen
bonded at one point (type B cable)
16 Typical installation of a screened and armoured
cable
Appendices
A Procedure for area classification
B Properties of combustible dusts
C Light metal construction and the associated
frictional sparking risks
D Selection of increased safety 'e' cage motors and
associated protection devices
E Illustrations of typical intrinsically safe
installations
F Certification of intrinsically safe electrical
apparatus and systems
G Examples of the more common combinations of
'earthed' circuits and screens
H Test for restricted-breathing
Electrical apparatus intended for use in explosive gas atmospheres under conditions where the hazard will be from combustible dust. Electrical apparatus is considered acceptable if it operates safely in an enclosure with a maximum dust layer thickness of five millimetres on its external surface.
Committee |
EXL/31
|
DevelopmentNote |
Supersedes 88/29111 DC (10/2005)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
EEMUA 186 : 2016 | A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS IEC 61831:1999 | On-line analyser systems. Guide to design and installation |
IP 6 : 4ED 82 | ASPHALTENES IN OIL - PRECIPITATION WITH NORMAL HEPTANE |
IP 54 : 1942 | SETTING POINT |
BS 6480:1988 | Specification for impregnated paper-insulated lead or lead alloy sheathed electric cables of rated voltages up to and including 33000 V |
BS 5958-2:1991 | Code of practice for control of undesirable static electricity Recommendations for particular industrial situations |
BS 5501-9:1982 | Electrical apparatus for potentially explosive atmospheres Specification for intrinsically safe electrical systems \'i\' |
BS 5501-4:1977 | Electrical apparatus for potentially explosive atmospheres Powder filling \'q\' |
BS 6467-2:1988 | Electrical apparatus with protection by enclosure for use in the presence of combustible dusts Guide to selection, installation and maintenance |
BS 7430:1991 | Code of practice for earthing |
BS 5501-7:1977 | Electrical apparatus for potentially explosive atmospheres Intrinsic safety \'i\' |
BS 5501-6:1977 | Electrical apparatus for potentially explosive atmospheres Increased safety \'e\' |
BS 5501-1:1977 | Electrical apparatus for potentially explosive atmospheres General requirements |
IP 5 : 1942 | ASH FROM GREASE |
BS 5501-5:1977 | Electrical apparatus for potentially explosive atmospheres Flameproof enclosure \'d\' |
BS 5345-2:1983 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Classification of hazardous areas |
BS 4568-2:1970 | Specification for steel conduit and fittings with metric threads of ISO form for electrical installations Fittings and components |
BS 6467-1:1985 | Electrical apparatus with protection by enclosure for use in the presence of combustible dusts Specification for apparatus |
BS 5501-8:1988 | Electrical apparatus for potentially explosive atmospheres Encapsulation \'m\' |
BS 6656:1991 | Guide to prevention of inadvertent ignition of flammable atmospheres by radio-frequency radiation |
BS 5501-2:1977 | Electrical apparatus for potentially explosive atmospheres Oil immersion \'o\' |
BS 4568-1:1970 | Specification for steel conduit and fittings with metric threads of ISO form for electrical installations Steel conduit, bends and couplers |
BS 5345-1:1989 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) General recommendations |
BS 4121:1967 | Specification for mechanical cable glands for rubber and plastics insulated cables |
BS 6941:1988 | Specification for electrical apparatus for explosive atmospheres with type of protection N |
BS 5501-3:1977 | Electrical apparatus for potentially explosive atmospheres Pressurized apparatus \'p\' |
BS 7361-1:1991 | Cathodic protection Code of practice for land and marine applications |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
BS 4999-101:1987 | General requirements for rotating electrical machines Specification for rating and performance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.