BS 7870-4.11(2011) : 2011
Current
The latest, up-to-date edition.
LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620)
Hardcopy , PDF
English
01-01-2011
Foreword
1 Scope
2 Normative references
3 Voltage designation
4 Construction and dimensions
5 Tests
6 Routine tests
7 Sample tests
8 Type tests
Annexes
Annex A (informative) - Guide to selection and use
of cables
Annex B (normative) - Information to be supplied
and items to be agreed
Annex C (informative) - Guidance on type tests
Annex D (normative) - Measurement of moisture
content of water blocking tape
Bibliography
Defines requirements for the construction, dimensions and mechanical and electrical properties of 19/33(36) kV single-core cables having either aluminium or copper conductors, cross-linked polyethylene (XLPE) extruded insulation, a lead alloy sheath and a medium density polyethylene (MDPE) oversheath.
Committee |
GEL/20/16
|
DevelopmentNote |
To be read in conjunction with BS 7870-1(2011) & BS 7870-2(2011). Supersedes BS 7870-4.11(1999) and 11/30214075 DC. (12/2011) Supersedes 16/30339582 DC. 2011 Edition Re-issued in June 2016 & incorporates AMD 1 2016. (07/2016)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
BS EN 12548:1999 | Lead and alloys. Lead alloy ingots for electric cable sheathing and for sleeves |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
BS EN 60228:2005 | Conductors of insulated cables |
BS EN 60811-1-3:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
BS EN 60811-2-1:1998 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests |
BS EN 60811-1-2:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.