Foreword
1 Scope
2 Normative references
3 Voltage designation
4 Conductors
5 Insulation
6 Identification of cores
7 Laying up
8 Manufacturer's identification
9 Testing
10 Routine tests
11 Sample tests
12 Type tests
13 Additional control or street lighting cores
14 Sealing and drumming
Annexes
Annex A (normative) - Additional requirements for
        insulated control or street lighting cores
Annex B (informative) - Guidance on type approval
Annex C (normative) - Slippage test
Bibliography

Defines requirements for the construction, dimensions and mechanical and electrical properties of polymeric insulated aerial bundled conductors (ABCs) of rated voltage 0.6/1(1.2) kV, designed for a maximum continuous conductor operating temperature of 75 degree C.

Committee
GEL/20/16
DevelopmentNote
To be read in conjunction with BS 7870-1(2011) & BS 7870-2(2011). Supersedes BS 7870-5(1999) and 11/30219798 DC. (12/2011)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of BS7870 specifies requirements for the construction, dimensions and mechanical and electrical properties of polymeric insulated aerial bundled conductors (ABCs) of rated voltage 0.6/1(1.2) kV, designed for a maximum continuous conductor operating temperature of 75°C.

This part of BS7870 specifies requirements for ABCs with the following:

  • two, four or five-core construction;

  • phase and neutral conductors of equal size and type;

  • conductor sizes from 25 mm2 up to and including 120 mm2;

  • optional, insulated control or street lighting cores (see AnnexA).

NOTE1 The fifth core in the five-core bundle is designated as a protective conductor (protective core), i.e. a conductor used for some measure of protection against electric shock.

NOTE2 Guidance on type approval is given in AnnexB.

HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
BS EN 50182:2001 Conductors for overhead lines. Round wire concentric lay stranded conductors
BS 7870-2:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test
BS 2627:1970 Specification for wrought aluminium for electrical purposes. Wire
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
IEC 60885-1:1987 Electrical test methods for electric cables. Part 1: Electrical tests for cables, cords and wires for voltages up to and including 450/750 V
BS EN 60228:2005 Conductors of insulated cables
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
BS EN 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables. Common test methods Methods specific to polypropylene and polypropylene compounds. Resistance to environmental stress cracking. Measurement of the melt flow index. Carbon black and/or mineral filter content measurement in PE by direct combustion. Measurement of carbon black content by TGA. Assessment of carbon black dispersion in polyethylene using a microscope
BS EN 60811-3-1:1995 Insulating and sheathing materials of electric cables. Common test methods. Methods specific to PVC compounds Pressure test at high temperature. Tests for resistance to cracking
HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
BS EN ISO 6892-1:2016 Metallic materials. Tensile testing Method of test at room temperature
BS EN 60811-2-1:1998 Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
BS 7870-1:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.