BS 7870-7.2:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring
Hardcopy , PDF
02-08-2013
English
16-06-2003
Foreword
1 Scope
2 Normative references
3 Voltage designation
4 General requirements
5 Cables without metallic coverings
6 Cables with metallic coverings
Annex A (informative) Guide to use
Bibliography
Defines requirements for the construction, dimensions and mechanical and physical properties of single core and 3-core cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR) insulated and halogen-free sheathed cables with aluminium or steel wire armouring, having reduced fire propagation performance and low emission of smoke when affected by fire.
Committee |
GEL/20/16
|
DevelopmentNote |
To be read in conjunction with BS 7870-1(1996) and BS 7870-2(1999). (06/2003) Inactive for the new design. (09/2008)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Standards | Relationship |
HD 622 S1:1996/A2:2005 | Identical |
BS 7870-7.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring |
HD 622 S1:1996/A2:2005 | Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
BS ISO 4589-2 : 1996 AMD 10627 | PLASTICS - DETERMINATION OF BURNING BEHAVIOUR BY OXYGEN INDEX - AMBIENT-TEMPERATURE TEST |
BS EN 60811-1-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
BS EN 60811-1-3:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
BS EN 60811-3-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to PVC compounds Pressure test at high temperature. Tests for resistance to cracking |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
BS 7870-7.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring |
ASTM D 5964 : 2016 : REDLINE | Standard Practice for Rubber IRM 901, IRM 902, and IRM 903 Replacement Oils for ASTM No. 1, ASTM No. 2, ASTM No. 3 Oils, and IRM 905 formerly ASTM No. 5 Oil |
BS EN 60811-2-1:1998 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests |
BS EN 50265-2-1:1999 | Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame |
BS 7870-2:1996 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
BS EN 60811-1-2:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods |
BS EN 60811-1-4:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Tests at low temperature |
BS EN 60811-3-2:1995 | Insulating and sheathing materials of electric cables. Common test methods Methods specific to PVC compounds - Loss of mass test. Thermal stability test |
HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |