1 Scope
2 Normative references
3 Definitions
4 Voltage designation and materials
5 Precautions against water penetration in cables
6 Cable characteristics
7 Accessory characteristics
8 Test categories and conditions
9 Routine tests on cables
10 Sample tests on cables
11 Type tests - Summary
12 Electrical type tests on cables
13 Type tests on cable components
14 Water penetration type test on complete cables
15 Mechanical and thermal type tests on complete cables
16 Type tests on accessories
17 Type tests on ancillary equipment
18 Electrical tests after installation
Bibliography
Describes tests and requirements for power cables with XLPE insulation and metallic sheath and their accessories for rated voltages from 66 kV (72.5 kV) to 132 kV (145 kV) for fixed installations. Also applies to single core cables and 3-core cables with separate cores and to their accessories for usual conditions of installation and operation.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 95/215801 DC. (11/2001) Reviewed and confirmed by BSI, December 2011. (11/2011)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 7970:2005 | Electric cables. Metallic wire and foil sheath constructions of power cables having XLPE insulation for rated voltages from 66kV (U<sub>m</sub> = 72.5 kV) to 132kV (U<sub>m</sub> = 145 kV) |
12/30244364 DC : 0 | BS 7970 - ELECTRIC CABLES - METAL FOIL AND LONGITUDINALLY WELDED ALUMINIUM SHEATH CONSTRUCTIONS OF POWER CABLES HAVING XLPE INSULATION FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7922:2004 | Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods |
03/308252 DC : DRAFT JUNE 2003 | BS 7970 - TESTS AND REQUIREMENTS FOR METALLIC WIRE AND FOIL SHEATH CONSTRUCTIONS OF POWER CABLES HAVING XLPE INSULATION FOR RATED VOLTAGES FROM 66 KV (UM = 72.5 KV) TO 132 KV (UM = 145 KV) |
BS 4727-2:GRP08(1994) : 1994 | GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
BS EN 60811-1-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
BS EN 60811-1-3:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test |
BS EN 60811-3-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to PVC compounds Pressure test at high temperature. Tests for resistance to cracking |
IEC 60230:1966 | Impulse tests on cables and their accessories |
BS EN 50062:1992 | Specification for ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
BS 6346:1997 | Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V |
BS 228:1994 | Specification for short-pitch transmission precision roller chains and chain wheels |
BS EN 60811-2-1:1998 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests |
BS EN 60811-1-2:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60885-2:1987 | Electrical test methods for electric cables. Part 2: Partial discharge tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.