BS 8573:2012
Current
The latest, up-to-date edition.
Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire
Hardcopy , PDF
English
31-10-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Conductors
6 Insulation
7 Identification of cores
8 Laying-up
9 Extruded optional inner covering
10 Sheath
11 Cable marking and additional information
12 Schedule of tests
13 Test conditions
14 Routine tests
15 Sample tests
16 Type tests
Annexes
Annex A (informative) - Guide to use
Annex B (normative) - Test for shrinkage of sheath
on cable
Annex C (normative) - Compatibility test
Annex D (normative) - Abrasion test
Annex E (informative) - Notes on type tests
Annex F (normative) - Green-and-yellow measurement
for shaped conductors
Bibliography
Describes requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000 V which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire compared with cables conforming to BS 7889.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes 12/30244462 DC. (10/2012)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000V which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire compared with cables conforming to BS7889.
NOTE1 These tests are published in separate British Standards to which reference is made at the appropriate point in the text. The Scope clauses of these British Standards contain cautionary notes concerning the applicability of such tests, and these should be taken into account when assessing the suitability of cables specified in this British Standard for use in a particular application.
Cables specified in this British Standard are intended for use in fixed installations in industrial areas, buildings and similar applications but not for burial in the ground, either directly or in ducts.
The cables specified in this British Standard are all stranded copper conductor, thermosetting insulated, thermoplastic sheathed types. There are single-core types and multi-core types (2-, 3-, 4- and 5-core).
In this standard, the level of corrosive (and acid) gases is determined by measurement of hydrochloric acid (HCl) in accordance with BSEN50267‑2‑1.
NOTE2 These are indirect assessment methods, and reference should be made to IEC/TS60695‑5‑2:2002, 5.1.5, for additional guidance.
The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum period of 5s).
NOTE3 Limitation on the temperature of the cables may be imposed in situations where they could be touched, or where they could touch other materials.
NOTE4 In installations that include wiring accessories, junction boxes and consumer units etc., the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.
NOTE5 AnnexA gives guidance on the use of these cables. AnnexB gives the test for shrinkage of sheath on cable. AnnexC gives the compatibility test. AnnexD gives the abrasion test. AnnexE contains notes on type tests, and AnnexF gives green-and-yellow measurement for shaped conductors.
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 60811-401:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven |
BS EN 61034-2 : 2005 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
BS EN 50262:1999 | Cable glands for electrical installations |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 50267-2-2:1999 | Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of degree of acidity of gases for materials by measuring pH and conductivity - Determination of degree of acidity of gases for materials by measuring pH and conductivity |
IEC TS 60695-5-2:2002 | Fire hazard testing - Part 5-2: Corrosion damage effects of fire effluent - Summary and relevance of test methods |
BS EN 61914:2016 | Cable cleats for electrical installations |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
BS EN 50267-2-1:1999 | Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 60332-3-24:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C |
BS EN 62275:2015 | Cable management systems. Cable ties for electrical installations |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS EN 60811-501 : 2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 501: MECHANICAL TESTS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES OF INSULATING AND SHEATHING COMPOUNDS |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
BS EN 50395 : 2005 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS EN 62230 : 2007 | ELECTRIC CABLES - SPARK-TEST METHOD |
BS EN 60811-503:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for sheaths |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 60684-2:2011 | Flexible insulating sleeving Methods of test |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS 8512:2008 | Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.