• Shopping Cart
    There are no items in your cart

BS 8573:2012

Current

Current

The latest, up-to-date edition.

Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-2012

€254.76
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Conductors
6 Insulation
7 Identification of cores
8 Laying-up
9 Extruded optional inner covering
10 Sheath
11 Cable marking and additional information
12 Schedule of tests
13 Test conditions
14 Routine tests
15 Sample tests
16 Type tests
Annexes
Annex A (informative) - Guide to use
Annex B (normative) - Test for shrinkage of sheath
        on cable
Annex C (normative) - Compatibility test
Annex D (normative) - Abrasion test
Annex E (informative) - Notes on type tests
Annex F (normative) - Green-and-yellow measurement
        for shaped conductors
Bibliography

Describes requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000 V which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire compared with cables conforming to BS 7889.

Committee
GEL/20/17
DevelopmentNote
Supersedes 12/30244462 DC. (10/2012)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000V which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire compared with cables conforming to BS7889.

NOTE1 These tests are published in separate British Standards to which reference is made at the appropriate point in the text. The Scope clauses of these British Standards contain cautionary notes concerning the applicability of such tests, and these should be taken into account when assessing the suitability of cables specified in this British Standard for use in a particular application.

Cables specified in this British Standard are intended for use in fixed installations in industrial areas, buildings and similar applications but not for burial in the ground, either directly or in ducts.

The cables specified in this British Standard are all stranded copper conductor, thermosetting insulated, thermoplastic sheathed types. There are single-core types and multi-core types (2-, 3-, 4- and 5-core).

In this standard, the level of corrosive (and acid) gases is determined by measurement of hydrochloric acid (HCl) in accordance with BSEN50267‑2‑1.

NOTE2 These are indirect assessment methods, and reference should be made to IEC/TS60695‑5‑2:2002, 5.1.5, for additional guidance.

The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum period of 5s).

NOTE3 Limitation on the temperature of the cables may be imposed in situations where they could be touched, or where they could touch other materials.

NOTE4 In installations that include wiring accessories, junction boxes and consumer units etc., the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.

NOTE5 AnnexA gives guidance on the use of these cables. AnnexB gives the test for shrinkage of sheath on cable. AnnexC gives the compatibility test. AnnexD gives the abrasion test. AnnexE contains notes on type tests, and AnnexF gives green-and-yellow measurement for shaped conductors.

BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 6724:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
BS 5467:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

BS EN 60811-401:2012 Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven
BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
BS EN 60229:2008 Electric cables. Tests on extruded oversheaths with a special protective function
BS EN 50262:1999 Cable glands for electrical installations
BS EN 60811-502:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations
BS EN 50267-2-2:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of degree of acidity of gases for materials by measuring pH and conductivity - Determination of degree of acidity of gases for materials by measuring pH and conductivity
IEC TS 60695-5-2:2002 Fire hazard testing - Part 5-2: Corrosion damage effects of fire effluent - Summary and relevance of test methods
BS EN 61914:2016 Cable cleats for electrical installations
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
BS EN 50393:2015 Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
BS EN 60228:2005 Conductors of insulated cables
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS EN 60332-3-24:2009 Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C
BS EN 62275:2015 Cable management systems. Cable ties for electrical installations
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS EN 60811-501 : 2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 501: MECHANICAL TESTS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES OF INSULATING AND SHEATHING COMPOUNDS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
BS EN 50395 : 2005 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
BS EN 60811-503:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for sheaths
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
BS EN 60684-2:2011 Flexible insulating sleeving Methods of test
BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
BS 7889:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations
BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS 8512:2008 Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.