• BS 8592:2016

    Current The latest, up-to-date edition.

    Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-03-2016

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    0 Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Rated voltage
    5 Conductors
    6 Insulation
    7 Identification of cable
    8 Cable marking and additional information
    9 Schedule of tests
    10 Test conditions
    11 Routine tests
    12 Sample tests
    13 Type tests
    Annexes
    Annex A (informative) - Guide to use and installation
            of cables
    Annex B (informative) - Notes on type tests
    Bibliography

    Abstract - (Show below) - (Hide below)

    Gives requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which: a) have a thermosetting insulation of rated voltage 450/750 V; b) provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test; c) emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; d) are flame retardant; and e) are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit. inside metal enclosures such as steel conduit.

    Scope - (Show below) - (Hide below)

    This British Standard specifies requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which: have a thermosetting insulation of rated voltage 450/750V; provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test; emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; are flame retardant; and are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit. This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings and similar applications, where maintenance of power supply during a fire is required for a defined period of time. NOTE1 Attention is drawn to the fact that the ability of a given cable to meet the test in this standard refers only to the test conditions stated, and the level of performance achieved in a particular installation can be influenced by actual installation conditions. The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum of 5s). NOTE2 AnnexA gives recommendations for the selection, installation and operation of cables. AnnexB gives notes on type tests.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/17
    Development Note Supersedes 15/30325295 DC. (04/2016)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 5266-1:2016 Emergency lighting Code of practice for the emergency lighting of premises

    Standards Referencing This Book - (Show below) - (Hide below)

    BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
    BS EN 50565-1:2014 Electric cables. Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) General guidance
    BS EN 60811-502:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations
    BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
    BS EN 60228:2005 Conductors of insulated cables
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS EN 50395 : 2005 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice
    BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
    IEC 60331-3:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure
    BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    BS EN 60754-1:2014 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content