BS EN 14453:2005
Current
The latest, up-to-date edition.
Devices to prevent pollution by backflow of potable water. Pipe interrupter with permanent atmospheric vent DN 10 to DN 20. Family D, type C
Hardcopy , PDF
English
25-01-2006
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Nominal sizes
5 Designation
6 Marking and technical documents
7 Symbolization
8 General design characteristics
9 Physico-chemical characteristics
10 Characteristics and tests
11 Acoustic characteristics
Annex A (normative) Sampling and test
sequence
Bibliography
Defines the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 degree C and for 1 h 90 degree C.
Committee |
B/504
|
DevelopmentNote |
Supersedes BS 6281-3(1982) and 02/103307 DC. (02/2006)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541. This document specifies: a) field of application; b) requirements for pipe interrupters with permanent atmospheric vent; c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20; d) test method and requirements for verifying these properties; e) marking and presentation; f) acoustics. This document specifies the characteristics of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20 that are suitable for use in drinking water systems at pressures up to 1 MPa (10 bar) and temperatures up to 65 °C and for 1 h 90 °C. Backflow protection devices integrated in flushing valves are similar to DC and are not covered under this document. The requirements are stated in EN 12541.
Standards | Relationship |
UNE-EN 14453:2005 | Identical |
NBN EN 14453 : 2005 | Identical |
SN EN 14453 : 2005 | Identical |
EN 14453:2005 | Identical |
UNI EN 14453 : 2005 | Identical |
NEN EN 14453 : 2005 | Identical |
NF EN 14453 : 2005 | Identical |
I.S. EN 14453:2005 | Identical |
NS EN 14453 : 1ED 2005 | Identical |
DIN EN 14453:2005-08 | Identical |
ISO 3822-1:1999 | Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement |
ISO 3822-4:1997 | Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4: Mounting and operating conditions for special appliances |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
EN 12541:2002 | Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10 |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
EN ISO 3822-4:1997 | Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 4: Mounting and operating conditions for special appliances |
ISO 7-1:1994 | Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 6509:1981 | Corrosion of metals and alloys Determination of dezincification resistance of brass |
ISO 9227:2017 | Corrosion tests in artificial atmospheres — Salt spray tests |
ISO 3822-3:1997 | Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances |
EN ISO 6509:1995 | Corrosion of metals and alloys - Determination of dezincification resistance of brass (ISO 6509:1981) |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.