BS EN 45544-1:2015
Current
The latest, up-to-date edition.

Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours General requirements and test methods
Hardcopy , PDF
English
28-02-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Test methods
6 Uncertainty of measurement and lower
limit of measurement
7 Test report
Annex A (normative) - Standard test gas volume
fractions for EN 45544-2 apparatus
Annex B (informative) - Sequence of tests
Annex C (informative) - Example of a test chamber
Annex D (informative) - Table of significant changes
in comparison to EN 45544-1:1999
Defines general requirements and test methods for the determination of the performance characteristics of personal, portable, transportable and fixed, continuous duty electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours in workplace atmospheres.
Committee |
EXL/31/1
|
DevelopmentNote |
Supersedes 96/206382 DC. (09/2005) Supersedes 13/30275012 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies general requirements and test methods for the determination of the performance characteristics of personal, portable, transportable and fixed, continuous duty electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours in workplace atmospheres.
This European Standard is applicable to apparatus whose primary purpose is to provide an indication, alarm and/or other output function to give a warning of the presence of a toxic gas or vapour in the atmosphere and, in some cases, to initiate automatic or manual protective actions. It is applicable to apparatus in which the sensor automatically generates an electrical signal when gas is present.
This European Standard is not applicable to apparatus:
-
used for the measurement of oxygen;
-
used only in laboratories for analysis or measurement;
-
used only for process measurement purposes;
-
used in car parks or tunnels;
-
used in the domestic environment;
-
used in environmental air pollution monitoring;
-
used for the measurement of combustible gases and vapours related to the risk of explosion.
It also does not apply to open-path (line of sight) area monitors.
For apparatus used for sensing the presence of multiple gases this standard applies only to the detection of toxic gas or vapour.
Standards | Relationship |
I.S. EN 45544-1:2015 | Identical |
NEN EN 45544-1 : 2015 | Identical |
NF EN 45544-1 : 2015 | Identical |
DIN EN 45544-1 : 2015 | Identical |
NBN EN 45544-1 : 2015 | Identical |
NS EN 45544-1 : 2015 | Identical |
EN 45544-1:2015 | Identical |
UNE-EN 45544-1:2000 | Identical |
EN 45544-1:2015 | Identical |
SN EN 45544-1 : 2015 | Identical |
BS 8008(1996) : 1996 | GUIDE TO SAFETY PRECAUTIONS AND PROCEDURES FOR THE CONSTRUCTION AND DESCENT OF MACHINE-BORED SHAFTS FOR PILING AND OTHER PURPOSES |
C22.2 NO. 205-17 | Signal equipment |
EN 50270:2015 | Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 45544-3 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 45544-2:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 45544-3:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection |
EN 45544-2 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.