• Shopping Cart
    There are no items in your cart

BS EN 50264-3-1:2008

Current

Current

The latest, up-to-date edition.

Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-08-2008

€263.42
Excluding VAT

Introduction
1 Scope
2 Normative references
3 Definitions
4 Rated voltage
5 Marking and identification
   5.1 Marking of cable
   5.2 Core identification
   5.3 Sheath
6 Construction of cables
   6.1 General
   6.2 Conductor
   6.3 Conductor screening
   6.4 Separator
   6.5 Insulation system
   6.6 Sheath
   6.7 Constructional components
7 Tests
   7.1 Definitions relating to tests
   7.2 Conductor resistance
   7.3 Voltage test
   7.4 Insulation resistance
   7.5 Dielectric strength
   7.6 Spark test
   7.7 DC stability
   7.8 Surface resistance
   7.9 Ageing test
   7.10 Hot set test
   7.11 Compatibility
   7.12 Water absorption test on sheath
   7.13 Ozone resistance
   7.14 Mineral oil resistance
   7.15 Fuel resistance
   7.16 Acid and alkali resistance
   7.17 Bending test at low temperature (cores and cables
        with OD <= 12,5 mm)
   7.18 Cold elongation test (cables with OD > 12,5 mm)
   7.19 Impact test at low temperature
   7.20 Reaction to fire - Cables
   7.21 Reaction to fire - Components
Annex A (normative) - Code designation
Bibliography

Defines requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: - 0,6/1 kV unscreened, unsheathed (1 mm[2] to 400 mm[2]); - 1,8/3 kV unscreened, unsheathed (1,5 mm[2] to 400 mm[2]); - 1,8/3 kV unscreened, sheathed (1,5 mm[2] to 400 mm[2]); - 3,6/6 kV unscreened, sheathed (2,5 mm[2] to 400 mm[2]).

Committee
GEL/20/12
DevelopmentNote
Supersedes 05/30137085 DC. (08/2008)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current

EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings:

  • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2);

  • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2);

  • 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2);

  • 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2).

All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is ncountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.

Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.

EN 50264-3-1 should be read in conjunction with Part 1 “General requirements??.

€263.42
Excluding VAT