• Shopping Cart
    There are no items in your cart

BS EN 50361:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Basic standard for the measurement of specific absorption rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)

Available format(s)

Hardcopy , PDF

Superseded date

29-09-2006

Language(s)

English

Published date

18-09-2001

€322.53
Excluding VAT

1 Scope
2 Normative references
3 Physical quantities, units and constants
  3.1 Physical quantities
  3.2 Constants
4 Definitions
5 Measurement system specifications
  5.1 General requirements
  5.2 Phantom specifications (shell and liquid)
  5.3 Specifications of the SAR measurement
      equipment
  5.4 Scanning system specifications
  5.5 Mobile phone holder specifications
  5.6 Other equipment
6 Protocol for SAR assessment
  6.1 Measurement preparation
  6.2 Tests to be performed
  6.3 Measurement procedure
  6.4 Post-processing
7 Uncertainty assessment
  7.1 General requirements
  7.2 Components contributing to uncertainty
  7.3 Uncertainty assessment
8 Measurement report
  8.1 General
  8.2 Items to be recorded in the test report
Annex A (informative) Phantom specifications
        A.1 Rationale for the phantom shape
        A.2 Tissue equivalent liquids
        A.3 Preparation of tissue equivalent
            material
        A.4 Measurement of the dielectric
            properties
Annex B (informative) Calibration of the measurement
                      equipment (linearity, isotropy,
                      sensitivity) and uncertainty
                      assessment
         B.1 Introduction
         B.2 Assessment of the sensitivity of the
             dipolar sensors
         B.3 Isotropy
         B.4 Linearity
         B.5 Lower detection limit
         B.6 Boundary effects
         B.7 Response time
Annex C (informative) Post-processing techniques and
                      uncertainty assessment
        C.1 Extrapolation and interpolation schemes
        C.2 Averaging scheme and maximum finding
Annex D (informative) Measurement system validation
        D.1 Simplified performance checking
        D.2 System validation

Applies to any electromagnetic field (EM) transmitting devices intended to be used with the radiating part of the equipment in close proximity to the human ear including mobile phones, cordless phones, etc. The frequency range is 300 MHZ to 3 GHz. The objective is to specify the method for demonstration of compliance with the specific absorption rate (SAR) limits for such equipment.

Committee
GEL/106
DevelopmentNote
Supersedes 00/243601 DC. (06/2005)
DocumentType
Standard
Pages
54
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
SN EN 50361 : 2001 Identical
DIN EN 50361 : 2002 Identical
UNE-EN 50361:2003 Identical
EN 50361:2001 Identical
NBN EN 50361 : 2002 Identical
NEN EN 50361 : 2001 Identical
I.S. EN 50361:2001 Identical
NF EN 50361 : 2001 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.