BS EN 50399:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results
Hardcopy , PDF
22-05-2019
English
31-05-2011
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Qualification of test apparatus
6 Test procedure
7 Determination of parameters derived from the test
8 Test report
Annex A (normative) - Calculation of heat release
Annex B (normative) - Smoke production
Annex C (informative) - Additional information on Reynolds
number in Figure 5
Annex D (normative) - Flow distribution inside the duct
Annex E (normative) - Commissioning calibrations
Annex F (informative) - Guidance for calibration procedures
for specific measuring equipment
Annex G (normative) - Calculation of HRR[av], SPR[av]
and FIGRA
Annex H (informative) - Guidance on the choice of test
equipment
Annex I (informative) - Guidance on the file format for
data from the test
Annex J (normative) - Rounding of numbers
Bibliography
Describes the apparatus and methods of test for the assessment of vertical flame spread, heat release, smoke production and occurrence of flaming droplets/particle of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.
Committee |
GEL/20/18
|
DevelopmentNote |
Supersedes 03/308231 DC. (05/2011) Supersedes 15/30329860 DC. 2011 Edition Re-issued in July 2016 & incorporates AMD 1 2016. 2011 Edition remains active & will be withdrawn on 18/04/2019. (07/2016)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
EN 50399 : 2011 AMD 1 2016 | Identical |
EN 50399:2011 | Identical |
NFPA 555 : 2017 | METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER |
BS 8492(2016) : 2016 | TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
EN ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003) |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2003) |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
EN 60332-3-10:2009 | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
EN 14390:2007 | Fire test - Large-scale room reference test for surface products |
EN 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.