BS EN 54-29:2015
Current
The latest, up-to-date edition.
Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of smoke and heat sensors
Hardcopy , PDF
English
30-04-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test and assessment and sampling methods
6 Assessment and verification of constancy of performance (AVCP)
7 Classification and designation
8 Marking, Labelling and Packaging
Annex A (normative) - Smoke tunnel for smoke response values
Annex B (normative) - Test aerosol for smoke response value
measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Heat tunnel for heat response value
Annex E (normative) - Apparatus for dazzling test
Annex F (informative) - Apparatus for impact test
Annex G (normative) - Fire test room
Annex H (normative) - Open wood fire (TF1)
Annex I (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex J (normative) - Glowing smouldering cotton fire (TF3)
Annex K (normative) - Open plastics (polyurethane) fire (TF4)
Annex L (normative) - Liquid (heptane) fire (TF5)
Annex M (normative) - Low temperature black smoke (decalene)
liquid fire (TF8)
Annex N (informative) - Information concerning the construction of
the smoke tunnel
Annex O (informative) - Construction of the heat tunnel
Annex P (informative) - Information concerning test procedures and
requirements for the response to slowly developing fires
Annex Q (informative) - Information concerning the construction of the
measuring ionization chamber
Annex ZA (informative) - Clauses of this European Standard addressing
the provisions of the EU Construction Products Regulation
Bibliography
Defines requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings, incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor.
Committee |
FSH/12/2
|
DevelopmentNote |
Supersedes 09/30208451 DC. (04/2015)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN. Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method). NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.
Standards | Relationship |
EN 54-29:2015 | Identical |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
16/30337833 DC : 0 | BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF SYSTEMS IN NON-DOMESTIC PREMISES |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
305/2011 : 2011 AMD 2 2014 | REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE) |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.