BS EN 55016-1-6 : 2015
Current
The latest, up-to-date edition.
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION
Hardcopy , PDF
English
01-01-2015
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Fundamental concepts
5 Calibration methods for the frequency
range 9 kHz to 30 MHz
6 Frequencies, equipment and functional
checks for calibrations at or above 30 MHz
7 Basic parameters and equations common
to antenna calibration methods for frequencies
above 30 MHz
8 Details for TAM, SAM, and SSM calibration
methods for frequencies of 30 MHz and above
9 Calibration procedures for specific antenna
types for frequencies of 30 MHz and above
Annex A (informative) - Background information
and rationale for the methods of antenna
calibration
Annex B (normative) - Calibration of biconical
antennas and tuned dipole antennas above
a ground plane using the TAM and the SAM
Annex C (informative) - Rationale for the equations
used in antenna calibration and relevant
information about antenna characteristics for
uncertainty analysis in the frequency range 30
MHz to 1 GHz
Annex D (informative) - Background information
and rationale for calibration of antennas at
frequencies above 1 GHz
Annex E (informative) - Notes for measurement
uncertainty budgets
Annex F (informative) - Mismatch uncertainties
from a two-port device connected between a
transmit port and a receive port
Annex G (informative) - Verification method for
calibration of monopole antennas and uncertainty
analysis of the ECSM
Annex H (informative) - Helmholtz coil method for
calibration of loop antennas up to 150 kHz
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Gives procedures and supporting information for the calibration of antennas for determining antenna factors (AF) that are applicable to antennas intended for use in radiated disturbance measurements.
Committee |
GEL/210/12
|
DevelopmentNote |
Supersedes 10/30230478 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
182
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 55016-1-6:2015/A1:2017 | Identical |
IEC 61000-4-22:2010 | Electromagnetic compatibility (EMC) - Part 4-22: Testing and measurement techniques - Radiated emissions and immunity measurements in fully anechoic rooms (FARs) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
IEEE 1309-2013 REDLINE | IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz |
CISPR 16-1-5:2014+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz |
CISPR 25:2016 | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers |
EN 55016-1-5:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016) |
ISO/IEC 17043:2010 | Conformity assessment — General requirements for proficiency testing |
MIL-STD-461 Revision G:2015 | REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT |
IEC 61169-16:2006 | Radio-frequency connectors - Part 16: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling - Characteristics impedance 50 ohms (75 ohms) (type N) |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
IEC 60050-726:1982 | International Electrotechnical Vocabulary (IEV) - Part 726: Transmission lines and waveguides |
IEEE 1128-1998 | IEEE Recommended Practice for Radio-Frequency (RF) Absorber Evaluation in the Range of 30 MHz to 5 GHz |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.