BS EN 60044-2:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Instrument transformers Inductive voltage transformers
Hardcopy , PDF
31-03-2012
English
30-06-2003
Foreword
1 General
1.1 Scope
1.2 Normative references
2 Definitions
2.1 General definitions
2.2 Additional definitions for single-phase
inductive protective voltage transformers
3 General requirements
4 Normal and special service conditions
4.1 Normal service conditions
4.2 Special service conditions
4.3 System earthing
5 Ratings
5.1 Standard values of rated voltages
5.2 Standard values of rated output
5.3 Standard values of rated voltage factor
5.4 Limits of temperature rise
6 Design requirements
6.1 Insulation requirements
6.2 Short-circuit withstand capability
6.3 Mechanical requirements
7 Classification of tests
7.1 Type tests
7.2 Routine tests
7.3 Special tests
8 Type tests
8.1 Temperature-rise test
8.2 Short-circuit withstand capability test
8.3 Impulse test on primary winding
8.4 Wet test for outdoor type transformers
8.5 Radio interference voltage measurement
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary
windings and partial discharge measurement
9.3 Power-frequency withstand tests between sections
and on secondary windings
10 Special tests
10.1 Chopped impulse test on primary winding
10.2 Measurement of capacitance and dielectric
dissipation factor
10.3 Mechanical tests
10.4 Transmitted overvoltage measurement
11 Markings
11.1 Rating plate markings
11.2 Terminal markings
12 Accuracy requirements for single-phase inductive
measuring voltage transformers
12.1 Accuracy class designation for measuring voltage
transformers
12.2 Limits of voltage error and phase displacement
for measuring voltage transformers
12.3 Type tests for accuracy of measuring voltage
transformers
12.4 Routine tests for accuracy of measuring voltage
transformers
12.5 Marking of the rating plate of a measuring voltage
transformer
13 Additional requirements for single-phase inductive
protective voltage transformers
13.1 Accuracy class designation for protective voltage
transformers
13.2 Limits of voltage error and phase displacement
for protective voltage transformers
13.3 Rated voltages for secondary windings intended to
produce a residual voltage
13.4 Output for secondary windings intended to produce
a residual voltage
13.5 Accuracy class for secondary windings intended to
produce a residual voltage
13.6 Type tests for protective voltage transformers
13.7 Routine tests for protective voltage transformers
13.8 Marking of the rating plate of a protective
voltage transformer
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Figures
Tables
Covers new inductive voltage transformers used with electrical measuring instruments and protective devices at frequencies from 15 Hz to 100 Hz. Deals with transformers having separate windings, as well as auto-transformers, where suitable, but not transformers used in laboratories.
Committee |
PEL/38
|
DevelopmentNote |
Supersedes BS 7625(1993). Also numbered as IEC 60044-2. Supersedes 98/202066 DC and 98/202857 DC. (08/2001) Supersedes 00/202267 DC. (07/2003) Together with BS EN 60044-5 supersedes BS 3941(1975). (09/2004)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 60044-2:1999/A2:2003 | Identical |
NBN EN 60044-2 : 2001 AMD 2 2003 | Identical |
SN EN 60044-2 : 1999 AMD 2 2003 | Identical |
I.S. EN 60044-2:1999 | Identical |
NF EN 60044-2 : 2000 AMD 2 2003 | Identical |
UNE-EN 60044-2:1999 | Identical |
BS 8431:2010 | Electrical static meters for secondary metering and sub-metering. Specification |
BS DD8431(2005) : 2005 | ELECTRICAL STATIC METERS FOR SECONDARY METERING AND SUB-METERING - SPECIFICATION |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
HD 587 : 200S1 | INSTRUMENT TRANSFORMERS - THREE-PHASE VOLTAGE TRANSFORMERS FOR VOLTAGE LEVELS HAVING UM UP TO 52 kV |
IEC 60028:1925 | International standard of resistance for copper |
EN 60721-3-1:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage |
HD 478.2.3 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - AIR PRESSURE |
HD 478.2.2 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - PRECIPITATION AND WIND |
HD 478.2.6 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - EARTHQUAKE VIBRATION AND SHOCK |
EN 60721-3-9:1993/A1:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
EN 60721-3-0:1993 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction |
HD 478.2.1 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - TEMPERATURE AND HUMIDITY |
EN 60721-3-7:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
HD 478.2.4 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - SOLAR RADIATION AND TEMPERATURE |
HD 566 : 200S1 | THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
HD 478.2.5 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - DUST, SAND, SALT MIST |
HD 478.2.7 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - FAUNA AND FLORA |
EN 60721-1:1995/A2:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
EN 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
EN 60721-3-6:1993/A2:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SHIP ENVIRONMENT |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.