• There are no items in your cart

BS EN 60076-13:2006

Current

Current

The latest, up-to-date edition.

Power transformers Self-protected liquid-filled transformers

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-11-2006

€156.59
Excluding VAT

1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Electrical characteristics
   5.1 Rated power
   5.2 Highest voltage for equipment
   5.3 Windings
   5.4 Tappings
   5.5 Connection group
   5.6 Dimensioning of the low-voltage winding neutral
        connection
   5.7 Short-circuit impedance
   5.8 Insulation levels and dielectric tests
   5.9 Temperature rise limits at rated power
   5.10 Overload capability
6 Self-protection and disconnection device (SPDD)
   6.1 Functional requirements
   6.2 Coordination principle
   6.3 Mechanical requirements
7 Constructional requirements
   7.1 Liquid preservation system
   7.2 Bushings
   7.3 Dielectric liquid and component materials
   7.4 Disconnection function
8 Information to be supplied by the customer
9 Information to be supplied by the manufacturer
10 Rating plate
11 Tests
   11.1 List and classification of tests (routine, type
        and special tests)
   11.2 Routine tests
   11.3 Type tests
   11.4 Short-circuit test with the self-protection and
        disconnection device disconnected or bypassed
12 Test procedure
   12.1 Measurement of partial discharges
   12.2 Transformer pressure test
   12.3 Switching cycle tests
   12.4 Behaviour test of self-protection and disconnection
        device
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Applies to high-voltage/low-voltage self-protected liquid-filled and naturally cooled transformers for rated power 50 kVA to 1000 kVA for indoor or outdoor use having a: - primary winding (high-voltage) with highest voltage for equipment up to 24 kV; - secondary winding (low-voltage) with highest voltage for equipment of 1,1 kV.

Committee
PEL/14
DevelopmentNote
Supersedes 04/30117440 DC (11/2006)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

Applies to high-voltage/low-voltage self-protected liquid-filled and naturally cooled transformers for rated power 50 kVA to 1 000 kVA for indoor or outdoor use having a primary winding (high-voltage) with highest voltage for equipment up to 24 kV; a secondary winding (low-voltage) with highest voltage for equipment of 1,1 kV.

Standards Relationship
IEC 60076-13:2006 Identical
DIN EN 60076-13 : 2007 Identical
I.S. EN 60076-13:2006 Identical
NBN EN 60076-13 : 2007 Identical
NF EN 60076-13 : 2007 Identical
EN 60076-13 : 2006 Identical

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
EN 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
IEC 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
IEC 60836:2015 Specifications for unused silicone insulating liquids for electrotechnical purposes
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
EN 60296:2012 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
EN 60836:2015 Specifications for unused silicone insulating liquids for electrotechnical purposes
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 60076-1:2011 Power transformers - Part 1: General
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 60282-1:2009/A1:2014 HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009)
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.