INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and classification
5 Standard ratings and service conditions
6 Requirements
7 General testing procedure
8 Type tests
9 Routine tests
10 Acceptance tests
Annex A (informative) - Example of a test circuit
        for the follow current interrupting test
Annex B (normative) - Mechanical considerations
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Describes surge arresters to protect the insulator assembly from lightning-caused overvoltages only.

Committee
PEL/37
DevelopmentNote
Supersedes 09/30167595 DC. (07/2011)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC 60099 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.

This standard defines surge arresters to protect the insulator assembly from lightning-caused overvoltages only. Therefore, and since the metal-oxide resistors are not permanently connected to the line, the following items are not considered for this standard:

  • switching impulse sparkover voltage;

  • residual voltage at steep current and switching current impulse;

  • thermal stability;

  • long-duration current impulse withstand duty;

  • power-frequency voltage versus time characteristics of an arrester;

  • disconnector test;

  • aging duties by power-frequency voltage.

Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc.

Designs with the EGLA\'s external series gap installed in parallel to an insulator are not covered by this standard.

Standards Relationship
IEC 60099-8:2017 Identical
EN 60384-14-2:2004 Identical
EN 60099-8:2011 Identical
IEC 60099-8:2011 Identical
IEC 60384-14-2:2004 Identical

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
ISO 4892-1:2016 Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
ISO 4287:1997 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions and surface texture parameters
EN ISO 4892-1:2016 Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016)
EN ISO 4892-3:2016 Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3:2016)
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
ISO 4892-3:2016 Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
ISO 3274:1996 Geometrical Product Specifications (GPS) — Surface texture: Profile method — Nominal characteristics of contact (stylus) instruments
ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
EN ISO 4892-2:2013 Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2:2013)
EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
EN ISO 3274:1997 Geometrical product specifications (GPS) - Surface texture: Profile method - Nominal characteristics of contact (stylus) instruments (ISO 3274:1996)