BS EN 60580:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Dose area product meters
Hardcopy , PDF
06-04-2020
English
15-08-2000
Committee |
CH/62/3
|
DevelopmentNote |
Supersedes 98/562295 DC. Also numbered as IEC 60580. (10/2005)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Specifies the performance and testing of dose area product meters with ionization chambers intended to measure dose area product and/or dose area product rate to which the patient is exposed during medical radiological examinations. The object of this International Standard is 1) to establish requirements for a satisfactory level of performance for dose area product meters, and 2) to standardize the methods for the determination of compliance with this level of performance.
Standards | Relationship |
UNE-EN 60580:2001 | Identical |
I.S. EN 60580:2000 | Identical |
EN 60580:2000 | Identical |
DIN EN 60580:2001-12 | Identical |
SN EN 60580 : 2000 | Identical |
NF EN 60580 : 2004 | Identical |
NBN EN 60580 : 2001 | Identical |
IEC 60731:2011+AMD1:2016 CSV | Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
IEC 60950:1999 | Safety of information technology equipment |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
EN 60417-1:2002 | GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - PART 1: OVERVIEW AND APPLICATION |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60601-1-1:2001 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
EN 60417-2:1999 | Graphical symbols for use on equipment - Part 2: Symbol originals |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 60731:2012 | Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
EN 61187:1994/corrigendum:1995 | ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION |
HD 501 : 200S1 | MEDICAL RADIOLOGY - TERMINOLOGY |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.