BS EN 60730-2-3:2007
Current
The latest, up-to-date edition.
Automatic electrical controls for household and similar use Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
Hardcopy , PDF
English
28-02-2009
Foreword
1 Scope and normative references
2 Definitions
3 General requirements
4 General notes on tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Overload and endurance
18 Mechanical strength
19 Threaded parts and connections
20 Creepage distances, clearances and distances through
solid insulation
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements - emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements - immunity
27 Abnormal operation
28 Guidance on the use of electronic disconnection
Annexes
Annex E (normative) - Circuit for measuring leakage current
Annex ZA (normative) - Normative references to
international publications with
their corresponding European
publications
Pertains to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps.
Committee |
CPL/72
|
DevelopmentNote |
Supersedes 88/20630 DC & BS 3955(1986). (12/2005) To be read in conjunction with BS EN 60730-1. Supersedes 00/241605 DC, 03/103715 DC & 04/30115370 DC. (03/2009)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1.
Standards | Relationship |
SN EN 60730-2-3 : 1993 AMD 11 2005 | Identical |
I.S. EN 60730-2-3:2007 | Identical |
UNE-EN 60730-2-3:2008 | Identical |
NF EN 60730-2-3 : 2008 | Identical |
DIN EN 60730-2-3 : 2008-06 | Identical |
EN 60730-2-3:2007 | Identical |
NEN EN 60730-2-3 : 1994 | Identical |
BS EN 60928:1995 | Auxiliaries for lamps. a.c. supplied electronic ballasts for tubular fluorescent lamps. General and safety requirements |
BS EN 61046:1995 | Specification for d.c. or a.c. supplied electronic step-down convertors for filament lamps. General and safety requirements |
EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.