• Shopping Cart
    There are no items in your cart

BS EN 61010-031:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Safety requirements for electrical equipment for measurement, control and laboratory use Safety requirements for hand-held probe assemblies for electrical measurement and test

Available format(s)

Hardcopy , PDF

Withdrawn date

20-05-2022

Language(s)

English

Published date

31-08-2015

€327.21
Excluding VAT

Committee
EPL/66
DevelopmentNote
Supersedes 98/230636 DC and BS EN 61010-2.031 (04/2002) Supersedes 05/30134820 DC. (03/2010) 2002 + A1 2008 Edition remains active & will be withdrawn on 03/07/2018. Supersedes 11/30244390 DC. (08/2015)
DocumentType
Standard
Pages
94
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

IEC 61010-031:2015 is available as IEC 61010-031:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC GUIDE 104. IEC 61010-031 is a stand-alone standard. This second edition cancels and replaces the first edition published in 2002 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes:
a) Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c.
b) Servicing is now included within the scope.
c) Extended environmental conditions are included within the scope.
d) New terms have been defined.
e) Tests for REASONABLY FORESEEABLE MISUSE have been added, in particular for fuses.
f) Additional instruction requirements for probe assembly operation have been specified.
g) Limit values for ACCESSIBLE parts and for measurement of voltage and touch current have been modified.
h) SPACINGS requirements for mating of CONNECTORS have been modified.
i) PROBE TIPS and SPRING-LOADED CLIPS requirements have been modified. The PROTECTIVE FINGERGUARD replace the BARRIER with new requirements.
j) Insulation requirements (6.5) and test procedures (6.6.5) have been rewritten and aligned when relevant with Part 1. Specific requirements have been added for solid insulation and thin-film insulation.
k) The terminology for MEASUREMENT CATEGORY I has been replaced with the designation \'not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV\'.
l) The flexing/pull test (6.7.4.3) has been partially rewritten.
m) Surface temperature limits (Clause 10) have been modified to conform to the limits of IEC Guide 117.
n) Requirements for resistance of PROBE WIRES to mechanical stresses have been added in Clause 12 and a new Annex D.
o) Requirements have been added regarding the prevention of HAZARD from arc flash and short-circuits for SPRING-LOADED CLIPS.
p) A new informative Annex E defines the dimension of the 4 mm banana CONNECTORS.

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60664-4:2005 Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 61180-2:1994 High-voltage test techniques for low-voltage equipment - Part 2: Test equipment
ISO/IEC Guide 51:2014 Safety aspects — Guidelines for their inclusion in standards
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
EN 61180-2:1994 High-voltage test techniques for low-voltage equipment - Part 2: Test equipment
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 61180-1:1994 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
IEC 60990:2016 Methods of measurement of touch current and protective conductor current