BS EN 61347-2-2:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
Hardcopy , PDF
18-12-2024
English
31-03-2012
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Transformer heating
16 Construction
17 Creepage distances and clearances
18 Screws, current-carrying parts and connections
19 Resistance to heat, fire and tracking
20 Resistance to corrosion
Annex A (normative) - Test to establish whether a
conductive part is a live part which may
cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means of
protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected
lamp controlgear
Annex E (normative) - Use of constant S other than
4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation
of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Particular additional requirements
for SELV d.c. or a.c. supplied electronic
step-down convertors for filament lamps
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1000 V at 50 Hz or 60 Hz and rated output voltage <= 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps.
Committee |
CPL/34/3
|
DevelopmentNote |
Together with BS EN 61347-1 supersedes BS EN 61046. (04/2001) Supersedes 98/263270 DC. To be read in conjunction with BS EN 61347-1 (03/2006) Supersedes 04/300380 DC. (05/2006) Supersedes 04/30115344 DC. (09/2007) Supersedes 07/30164768 DC. (03/2012)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV.
This publication is to be read in conjunction with IEC 61347-1:2007.
Standards | Relationship |
IEC 61347-2-2:2011 | Identical |
DIN EN 61347-2-2 : 2012 | Identical |
SN EN 61347-2-2 : 2001 AMD 2 2006 | Identical |
EN 61347-2-2:2012 | Identical |
UNE-EN 61347-2-2:2012 | Identical |
NF EN 61347-2-2 : 2012 | Identical |
I.S. EN 61347-2-2:2012 | Identical |
EN 60745-2-6:2003/A1:2006 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61558-2-16:2009/A1:2013 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013) |
EN 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-16:2009+AMD1:2013 CSV | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |