FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Protection of associated components
16 Abnormal conditions
17 Behaviour of the control gear at end of lamp life
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annex A (normative) - Test to establish whether
        a conductive part is a live part whic
        may cause an electric shock
Annex B (normative) - Particular requirements for
        thermally protected lamp control gear
Annex C (normative) - Particular requirements for
        electronic lamp control gear with
        means of protection against overheating
Annex D (normative) - Requirements for carrying out
        the heating tests of thermally protected
        lamp control gear
Annex E (normative) - Use of constant S other than
        4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
        the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Measurement of high-frequency
        leakage current
Annex J (normative) - Particular additional safety
        requirements for a.c., a.c./d.c. or d.c.
        supplied electronic control gear for emergency
        lighting
Annex K (informative) - Components used in the
        asymmetric pulse test circuit
Annex L (normative) - Information for control gear design
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Describes particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.

Committee
CPL/34/3
DevelopmentNote
Together with BS EN 61347-1, it supersedes BS EN 60928. Supersedes 98/263271 DC (10/2003) Supersedes 02/208567 DC. (11/2004) Supersedes 04/300381 DC. (07/2006) Supersedes BS EN 61347-2-4, BS EN 61347-2-5, BS EN 61347-2-6 & 07/30164732 DC. (12/2011)
DocumentType
Standard
Pages
56
PublisherName
British Standards Institution
Status
Superseded
Supersedes

IEC 61347-2-3:2011 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition cancels and replaces the first edition published in 2000, its Amendment 1 (2004) and its Amendment 2 (2006), IEC 61347-2-4 published in 2000, IEC 61347-2-5 published in 2000 and IEC 61347-2-6 published in 2000. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:
- rectifying test conditions when dimming;
- construction requirements;
- measurement circuits and limits for HF leakage currents;
- modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.

This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy.

IEC 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 60929:2011/A1:2016 AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
EN 61347-2-7:2012 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC 61347-2-7:2011+AMD1:2017 CSV Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
EN 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
IEC TS 60479-2:2007 Effects of current on human beings and livestock - Part 2: Special aspects
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.