BS EN 61347-2-3:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Lamp control gear Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
Hardcopy
14-03-2018
English
31-12-2011
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Protection of associated components
16 Abnormal conditions
17 Behaviour of the control gear at end of lamp life
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annex A (normative) - Test to establish whether
a conductive part is a live part whic
may cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp control gear
Annex C (normative) - Particular requirements for
electronic lamp control gear with
means of protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected
lamp control gear
Annex E (normative) - Use of constant S other than
4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Measurement of high-frequency
leakage current
Annex J (normative) - Particular additional safety
requirements for a.c., a.c./d.c. or d.c.
supplied electronic control gear for emergency
lighting
Annex K (informative) - Components used in the
asymmetric pulse test circuit
Annex L (normative) - Information for control gear design
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.
Committee |
CPL/34/3
|
DevelopmentNote |
Together with BS EN 61347-1, it supersedes BS EN 60928. Supersedes 98/263271 DC (10/2003) Supersedes 02/208567 DC. (11/2004) Supersedes 04/300381 DC. (07/2006) Supersedes BS EN 61347-2-4, BS EN 61347-2-5, BS EN 61347-2-6 & 07/30164732 DC. (12/2011)
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Supersedes |
IEC 61347-2-3:2011 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition cancels and replaces the first edition published in 2000, its Amendment 1 (2004) and its Amendment 2 (2006), IEC 61347-2-4 published in 2000, IEC 61347-2-5 published in 2000 and IEC 61347-2-6 published in 2000. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:
- rectifying test conditions when dimming;
- construction requirements;
- measurement circuits and limits for HF leakage currents;
- modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.
This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy.
Standards | Relationship |
I.S. EN 61347-2-3:2011 | Identical |
SN EN 61347-2-3 : 2011 AMD 1 2017 | Identical |
NF EN 61347-2-3 : 2012 AMD 1 2017 | Identical |
IEC 61347-2-3:2011+AMD1:2016 CSV | Identical |
DIN EN 61347-2-3 : 2017 | Identical |
EN 61347-2-3:2011/A1:2017 | Identical |
UNE-EN 61347-2-3:2012 | Identical |
EN 61347-2-3:2011 | Identical |
IEC 61347-2-3:2011/COR1:2011 | Identical |
IEC 61347-2-3:2011 | Identical |
EN 61347-1:2008 | Identical |
EN 61347-2-3:2011/AC:2011 | Identical |
IEC 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 60929:2011/A1:2016 | AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
IEC 60929:2011+AMD1:2015 CSV | AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
EN 61347-2-7:2012 | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
EN 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
IEC TS 60479-2:2007 | Effects of current on human beings and livestock - Part 2: Special aspects |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.