BS EN 61347-2-7:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lamp controlgear Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
Hardcopy , PDF
12-08-2019
English
31-03-2012
Committee |
CPL/34/3
|
DevelopmentNote |
Supersedes 98/263275 DC (10/2003) Together with 61347-1, -2-4, -2-5 and -2-6, it supersedes BS EN 60924. Supersedes 03/320435 DC (02/2007) Supersedes 08/30187424 DC. (03/2012)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7.
This publication is to be read in conjunction with IEC 61347-1:2007.
Standards | Relationship |
DIN EN 61347-2-7 : 2012 | Identical |
NF EN 61347-2-7 : 2012 | Identical |
EN 61347-2-7:2012 | Identical |
I.S. EN 61347-2-7:2012 | Identical |
UNE-EN 61347-2-7:2012 | Identical |
IEC 61347-2-7:2011+AMD1:2017 CSV | Identical |
SN EN 61347-2-7 : 2001 | Identical |
EN 50106:2008 | Identical |
IEC 61347-2-7:2011 | Identical |
IEC 62368-1:2014/COR1:2015 | Identical |
BS 5266-1:2016 | Emergency lighting Code of practice for the emergency lighting of premises |
BIP 2081 : 2012 | A GUIDE TO EMERGENCY LIGHTING |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61558-2-16:2009/A1:2013 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013) |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 61558-2-16:2009+AMD1:2013 CSV | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 60929:2011/A1:2016 | AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
IEC 60929:2011+AMD1:2015 CSV | AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 61347-2-3:2011/A1:2017 | LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS (IEC 61347-2-3:2011/A1:2016) |
EN 60921:2004/A1:2006 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
EN 60901:1996/A6:2017 | SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED) |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60598-2-22:2014/AC:2016-09 | LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING (IEC 60598-2-22:2014/COR2:2016) |
EN 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.