• Shopping Cart
    There are no items in your cart

BS EN 61378-1:2011

Current

Current

The latest, up-to-date edition.

Convertor transformers Transformers for industrial applications

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-01-2012

€327.21
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and acronyms
4 Classification
5 Ratings
6 Load loss and voltage drop in transformers
  and reactors
7 Tests for converter transformers
8 On load noise level with transductors
  and/or IPT
Annex A (informative) - Determination of transformer
        service load loss at rated non-sinusoidal
        converter current from measurements with
        rated transformer current of fundamental
        frequency
Annex B (informative) - Short-circuit test currents
        and load losses in transformers for single-way
        converters (total loss injection)
Annex C (informative) - Current sharing measurement
        in high current valve windings
Annex D (informative) - Examples of duty cycles
Annex E (informative) - Guidelines for design review
Annex F (informative) - Determination of loss in
        transformer tank due to magnetic field. 3D
        simulation and guidelines for tank losses
        evaluation and tank hotspot calculation
Annex G (informative) - Short-circuit measurements of
        rectifier transformers equipped with built in
        transductors
Annex H (informative) - Determination of the transformer
        voltage ratio and phase displacement by the
        turn ratio measurements
Annex I (informative) - Phase displacement connections
        and terminal indications of converter transformers
Annex J (normative) - Correlation between IEC 61378-1
        and IEC 60146-1-1 ratings
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Defines the specification, design and testing of power transformers and reactors which are intended for integration within semiconductor converter plants; it is not applicable to transformers designed for industrial or public distribution of a.c. power in general.

Committee
PEL/14
DevelopmentNote
Supersedes 92/28981 DC. (11/2005) Supersedes 08/30178668 DC. (01/2012)
DocumentType
Standard
Pages
98
PublisherName
British Standards Institution
Status
Current
Supersedes

This Part of IEC 61378 deals with the specification, design and testing of power transformers and reactors which are intended for integration within semiconductor converter plants; it is not applicable to transformers designed for industrial or public distribution of a.c. power in general.

The scope of this International Standard is limited to application of power converters of any power rating. Typical applications are: thyristor rectifiers for electrolysis; diode rectifiers for electrolysis; thyristor rectifiers for large drives; thyristor rectifiers for scrap melting furnaces, and diode rectifiers feeding inverters for variable speed drives. The standard also covers the regulating unit utilized in such application as step down regulating transformers or autotransformers. The valve winding highest voltage for equipment is limited to 36 kV.

This standard is not applicable to transformers for HVDC power transmission. These are highvoltage transformers, and they are subjected to d.c. voltage tests.

The standards for the complete converter plant (IEC 60146 series, or other publications dedicated to particular fields of application) may contain requirements of guarantees and tests (such as insulation and power loss) for the whole plant, including the converter transformer and possibly auxiliary transformers and reactor equipment. This does not relieve the application of the requirements of this standard concerning the guarantees and tests applicable to the converter transformer itself as a separate component before being assembled with the remainder of the converter plant.

The guarantees, service and type tests defined in this standard apply equally to transformers supplied as part of an overall converter package, or to those transformers ordered separately but for use with converter equipment. Any supplementary guarantee or special verification has to be specifically agreed in the transformer contract.

The converter transformers covered by this standard may be of the oil-immersed or dry-type design. Unless specific exceptions are stated in this standard, the transformers comply with IEC 60076 series for oil-immersed transformers, and with IEC 60076-11 for dry-type transformers.

NOTE For some converter applications, it is possible to use common distribution transformers of standard design. The use of such standard transformers in the special converter applications may require a certain derating. This matter is not specifically covered in this standard, which deals with the requirements to be placed on specially designed units. It is possible to estimate this derating from the formulae given in 5.1, and also from Clause 9 of IEC 60076-8:1997.

This standard deals with transformers with one or more active parts installed in the same tank like regulating (auto)transformer and one or two rectifier transformers. It also covers transformers with transductors and/or one or more interphase transformers.

For any combination not listed above an agreement between the purchaser and manufacturer is necessary regarding the determination and the measurement of the total losses.

This standard deals with transformers star Y and delta D and any other phase shifting connections (like zig-zag, extended delta, polygon etc.). Phase shifting windings can be placed on either the regulating or rectifier transformer.

Standards Relationship
IEC 61378-1:2011/COR1:2012 Identical
UNE-EN 61378-1:2012 Identical
SN EN 61378-1 : 1998 Identical
NBN EN 61378-1 : 2012 Identical
EN 61378-1:2011 Identical
DIN EN 61378-1 : 2012 Identical
NF EN 61378-1 : 2014 Identical
IEC 61378-1:2011 Identical

IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
IEC 60146-1-3:1991 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
IEC TR 60616:1978 Terminal and tapping markings for power transformers
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60050-551:1998 International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics
IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
IEC 60076-8:1997 Power transformers - Part 8: Application guide
IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60050-421:1990 International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors
IEC TR 60146-1-2:2011 Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60076-6:2007 Power transformers - Part 6: Reactors
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
IEC 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
IEC 61378-3:2015 Converter transformers - Part 3: Application guide
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC TS 60076-14:2009 Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 60076-6:2008 Power transformers - Part 6: Reactors

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.