BS EN 61897:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Overhead lines. Requirements and tests for Stockbridge type aeolian vibration dampers
Hardcopy , PDF
22-04-2020
English
15-02-1999
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Design
4.2 Materials
4.3 Mass, dimensions and tolerances
4.4 Protection against corrosion
4.5 Manufacturing appearance and finish
4.6 Marking
4.7 Installation instructions
5 Quality assurance
6 Classification of tests
6.1 Type tests
6.1.1 General
6.1.2 Application
6.2 Sample tests
6.2.1 General
6.2.2 Application
6.2.3 Sampling, acceptance criteria
6.3 Routine tests
6.3.1 General
6.3.2 Application and acceptance criteria
6.4 Table of tests to be applied
7 Test methods
7.1 Visual examination
7.2 Verification of dimensions, materials and mass
7.3 Corrosion protection tests
7.3.1 Hot dip galvanized components (other than
messenger cable wires)
7.3.2 Ferrous components protected from corrosion
by methods other than hot dip galvanizing
7.3.3 Hot dip galvanized messenger cable wires
7.4 Non-destructive tests
7.5 Clamp slip test
7.6 Breakaway bolt test
7.7 Clamp bolt tightening test
7.8 Attachment of weights to messenger cable
7.9 Attachment of clamp to messenger cable test
7.10 Corona and radio interference voltage (RIV) tests
7.11 Damper performance tests
7.11.1 Performance test variants
7.11.2 Damper characteristic test
7.11.3 Damper effectiveness evaluation
7.11.3.1 Methods of evaluation
7.11.3.2 Laboratory test
7.11.3.3 Field test
7.11.3.4 Analytical method
7.12 Damper fatigue test
7.12.1 Test methods
7.12.2 Swept frequency method
7.12.3 Resonant frequency method
7.12.4 Acceptance criteria
Annex A (normative) Minimum technical details to be agreed
between purchaser and supplier
Annex B (informative) Examples of graphs relevant to damper
characteristic test
Annex C (normative) Wind power input curve
Annex ZA Normative references to international publications
with their corresponding European publications
Bibliography
Applicable to Stockbridge type aeolian vibration dampers meant for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor.
Committee |
PEL/11
|
DevelopmentNote |
Supersedes 96/207923 DC. Also numbered as IEC 61897. (09/2005)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61897 : 2001 | Identical |
SN EN 61897 : 1998 | Identical |
EN 61897:1998 | Identical |
NBN EN 61897 : 1999 | Identical |
UNE-EN 61897:2000 | Identical |
I.S. EN 61897:1999 | Identical |
DIN EN 61897 : 1999 | Identical |
ISO 3951:1989 | Sampling procedures and charts for inspection by variables for percent nonconforming |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
IEC 60888:1987 | Zinc-coated steel wires for stranded conductors |
ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
IEC 60050-466:1990 | International Electrotechnical Vocabulary (IEV) - Part 466: Overhead lines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.