Protection against lightning Physical damage to structures and life hazard
Hardcopy , PDF
English
30-06-2011
Committee |
GEL/81
|
DevelopmentNote |
Together with BS EN 62305-1, BS EN 62305-2 and BS EN 62305-4, supersedes BS 6651(1999). Supersedes 03/305097 DC. (10/2006) Supersedes 07/30174641 DC. (06/2011)
|
DocumentType |
Standard
|
Pages |
162
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 62305-3:2010 provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to living beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
1) Minimum thicknesses of metal sheets or metal pipes given in Table 3 for air-termination systems are assumed as not able to prevent hot-spot problems.
2) Steel with electro-deposited copper is introduced as material suitable for LPS.
3) Some cross-sectional areas of LPS conductors were slightly modified.
4) For bonding purposes, isolating spark gaps are used for metal installations and SPD for internal systems.
5) Two methods simplified and detailed are provided for evaluation of separation distance.
6) Protection measures against injuries of living beings due to electric shock are considered also inside the structure.
7) Improved information for LPS in the case of structures with a risk of explosion are given in Annex D (normative).
This bilingual version (2012-06) corresponds to the monolingual English version, published in 2010-12.
Standards | Relationship |
DIN EN 62305-3:2011-10 | Identical |
I.S. EN 62305-3:2011 | Identical |
UNE-EN 62305-3:2011 | Identical |
EN 62305-3:2011 | Identical |
NF EN 62305-3 : 2012 | Identical |
NBN EN 62305-3 : 2011 | Identical |
SN EN 62305-3 : 2006 | Identical |
IEC 62305-1:2010 | Identical |
BS 6037-1:2017 | Planning, design, installation and use of permanently installed access equipment. Code of practice Suspended access equipment |
17/30342093 DC : 0 | BS 6037-1 - PLANNING, DESIGN, INSTALLATION AND USE OF PERMANENTLY INSTALLED ACCESS EQUIPMENT - CODE OF PRACTICE - PART 1: SUSPENDED ACCESS EQUIPMENT |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 5974:2017 | Planning, design, setting up and use of temporary suspended access equipment. Code of practice |
BS 7430(2011) : 2011 | CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
BS 8591:2014 | Remote centres receiving signals from alarm systems. Code of practice |
13/30286749 DC : 0 | BS 8591 - REMOTE CENTRES RECEIVING SIGNALS FROM ALARM SYSTEMS - CODE OF PRACTICE |
BS 5979:2007 | Remote centres receiving signals from fire and security systems. Code of practice |
07/30140559 DC : 0 | BS 8298-4 - CODE OF PRACTICE FOR THE DESIGN AND INSTALLATION OF NATURAL STONE CLADDING AND LINING - PART 4: RAINSCREEN AND STONE ON METAL FRAME CLADDING SYSTEMS |
15/30095322 DC : 0 | BS 5427 - CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS |
11/30249994 DC : DRAFT JULY 2011 | BS 7430 - CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 50164-2:2008 | Lightning Protection Components (LPC) - Part 2: Requirements for conductors and earth electrodes |
IEC 60728-11:2016 | Cable networks for television signals, sound signals and interactive services - Part 11: Safety |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
EN 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
EN 50164-7:2008 | Lightning Protection Components (LPC) - Part 7: Requirements for earthing enhancing compounds |
IEC 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
EN 50164-6:2009 | Lightning Protection Components (LPC) - Part 6: Requirements for lightning strike counters |
EN 60079-10-2:2015 | Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
IEC 62561-1:2017 | Lightning protection system components (LPSC) - Part 1: Requirements for connection components |
EN 50164-5:2009 | Lightning Protection Components (LPC) - Part 5: Requirements for earth electrode inspection housings and earth electrode seals |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 62561-3:2017 | Lightning protection system components (LPSC) - Part 3: Requirements for isolating spark gaps (ISG) |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
EN 62561-3:2017 | Lightning Protection System Components (LPSC) - Part 3: Requirements for isolating spark gaps (ISG) |
EN 50164-3 : 2006 AMD 1 2009 | LIGHTNING PROTECTION COMPONENTS (LPC) - PART 3: REQUIREMENTS FOR ISOLATING SPARK GAPS |
EN 61643-21:2001/A2:2013 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012) |
EN 62305-2:2012 | Protection against lightning - Part 2: Risk management |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
EN 50164-1:2008 | Lightning Protection Components (LPC) - Part 1: Requirements for connection components |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
EN 62561-1:2017 | Lightning Protection System Components (LPSC) - Part 1: Requirements for connection components |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
EN 50164-4:2008 | Lightning Protection Components (LPC) - Part 4: Requirements for conductor fasteners |