1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Method of measurement and
calculation of the efficiency of controlgear
(transformer, convertor) for tungsten halogen
lamps and for LED modules
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Specifies a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules.
Committee |
CPL/34/3
|
DevelopmentNote |
Supersedes 12/30261933 DC. (07/2014)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This part of the IEC 62442 series defines a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules.
Also a calculation method of the efficiency for the mentioned controlgear for halogen lamps and LED modules is defined.
This part of IEC 62442 applies to electrical controlgear – lamp circuits comprised solely of the controlgear and of the lamp(s).
For multipurpose power supplies only the lighting part will be considered.
NOTE 1 Requirements for testing individual controlgear during production are not included.
It specifies the measurement method for the total input power, the standby power and the calculation method of the controlgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with halogen lamps and LED modules.
This part of IEC 62442 does not apply to:
controlgear which form an integral part of lamps;
controlgear circuits with capacitors connected in series;
controllable wire-wound electromagnetic controlgear.
Standards | Relationship |
EN 62442-3:2014/A11:2017 | Identical |
IEC 62442-3:2014 | Identical |
EN 62442-3:2014 | Identical |
EN 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
IEC 61347-2-13:2014+AMD1:2016 CSV | Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 61347-2-13:2014/A1:2017 | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
EN 62384:2006/A1:2009 | DC OR AC SUPPLIED ELECTRONIC CONTROL GEAR FOR LED MODULES - PERFORMANCE REQUIREMENTS |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
IEC 62384:2006+AMD1:2009 CSV | DC or AC supplied electronic control gear for LED modules - Performance requirements |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC GUIDE 115:2007 | Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector |
IEC 62442-1:2011 | Energy performance of lamp controlgear - Part 1: Controlgear for fluorescent lamps - Method of measurement to determine the total input power of controlgear circuits and the efficiency of the controlgear |
EN 62442-2:2014/A11:2017 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 2: CONTROLGEAR FOR HIGH INTENSITY DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) - METHOD OF MEASUREMENT TO DETERMINE THE EFFICIENCY OF THE CONTROLGEAR |
IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 62442-1:2011/A11:2017 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR |
EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.