BS EN 62585:2012
Current
The latest, up-to-date edition.
Electroacoustics. Methods to determine corrections to obtain the free-field response of a sound level meter
Hardcopy , PDF
English
30-11-2012
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Uncertainties of measurement
6 General requirements for measurement of
adjustment value and corrections
7 Submission and inspection
8 Determination of the adjustment value at
the calibration check frequency
9 Determination of corrections for the typical
effects of reflections from the case of the sound
level meter and diffraction of sound around the
microphone
10 Determination of corrections for the deviation
of the microphone free-field frequency response
from a uniform frequency response
11 Determination of corrections for the use of
windscreens and similar accessories
12 Determination of corrections over a range of
frequencies when a sound calibrator is recommended
for use by the sound level meter manufacturer
13 Determination of corrections over a range of
frequencies when a comparison coupler is
recommended for use by the sound level meter
manufacturer
14 Determination of corrections over a range of
frequencies when an electrostatic actuator is
recommended for use by the sound level meter
manufacturer
15 Documentation
Annex A (normative) - Calibration check frequency
- Determination of the adjustment value
Annex B (normative) - Determination of the effects
of reflections from the case of the sound level
meter and diffraction of sound around the
microphone
Annex C (normative) - Determination of the effects
of the use of windscreens and similar accessories
Annex D (informative) - Determination of corrections
for use with sound calibrators to determine
equivalent free-field response at all frequencies
of interest
Annex E (informative) - Determination of corrections
for use with comparison couplers to determine
equivalent free-field frequency response at all
frequencies of interest
Annex F (informative) - Determination of corrections
for use with electrostatic actuators to determine
equivalent free-field frequency response at all
frequencies of interest
Annex G (informative) - Comparison techniques
Annex H (informative) - Exact one-twelfth-octave
frequencies
Annex I (informative) - Example calculations of
expanded uncertainty of measurement
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Gives information on the corrections required over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3.
Committee |
EPL/29
|
DevelopmentNote |
Supersedes 10/30194376 DC. (11/2012)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 62585:2012 provides information on the corrections required over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3. These corrections include; corrections for the typical effects of reflections from the case of the sound level meter and diffraction of sound around the microphone; corrections for the deviation of the typical microphone frequency response from a uniform frequency response, where the actual microphone response cannot be measured; and corrections for the influence on the frequency response of a typical microphone of a specified windscreen and any other accessory that is part of the configuration for normal use of the particular sound level meter submitted for testing. This International Standard includes discussion about uncertainties of measurement of the required corrections. In some instances a maximum permitted expanded uncertainty for the manufacturer or testing laboratory is given. The aim of this International Standard is to ensure that the adjustment value at the calibration check frequency and all corrections are determined using consistent and appropriate methods. It is intended that this International Standard will be used by manufacturers to determine adjustment values and corrections, by laboratories performing pattern evaluation tests according to IEC 61672-2, and by laboratories performing periodic tests according to IEC 61672-3. Laboratories performing periodic tests according to IEC 61672-3 will also need to consult this International Standard to ensure that the expanded uncertainties of measurement for the corrections quoted by the manufacturer do not exceed the maximum permitted values.
Standards | Relationship |
IEC 62585:2012 | Identical |
EN 62585 : 2012 | Identical |
IEC 61672-2:2013+AMD1:2017 CSV | Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests |
EN 61183:1994 | Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters |
IEC 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
IEC 61183:1994 | Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters |
IEC TS 61094-7:2006 | Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones |
EN 61672-2:2013/A1:2017 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017) |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
EN 61094-6:2005 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
IEC 61094-3:2016 | Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 61672-3:2013 | Electroacoustics - Sound level meters - Part 3: Periodic tests |
IEC 61094-8:2012 | Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
IEC 61672-3:2013 | Electroacoustics - Sound level meters - Part 3: Periodic tests |
IEC 61094-6:2004 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
EN 60942:2003 | Electroacoustics - Sound calibrators |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.