BS EN ISO 11137-3:2017
Current
The latest, up-to-date edition.
Sterilization of health care products. Radiation Guidance on dosimetric aspects of development, validation and routine control
Hardcopy , PDF
English
23-08-2017
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Measurement of dose
5 Establishing the maximum acceptable dose
6 Establishing the sterilization dose
7 Installation qualification
8 Operational qualification
9 Performance qualification
10 Routine monitoring and control
Annex A (informative) - Mathematical modelling
Annex B (informative) - Tables of references for
dosimetry-related testing during IQ/OQ/PQ
Annex C (informative) - Tolerances associated with
doses used in sterilization dose setting/substantiation
in ISO 11137-2 and ISO/TS 13004
Annex D (informative) - Application of dose measurement
uncertainty in setting process target doses
Bibliography
Provides guidance on meeting the requirements in ISO 11137-1 and ISO 11137-2 and in ISO/TS 13004 relating to dosimetry and its use in development, validation and routine control of a radiation sterilization process.
Committee |
CH/198
|
DevelopmentNote |
Supersedes 04/30081279 DC. (03/2007) Together with BS EN ISO 11137-1 and BS EN ISO 11137-2, it supersedes BS EN 552. (06/2007) Supersedes 15/30282559 DC. (09/2017)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document gives guidance on meeting the requirements in ISO11137‑1 and ISO11137‑2 and in ISO/TS13004 relating to dosimetry and its use in development, validation and routine control of a radiation sterilization process.
Standards | Relationship |
NF EN ISO 11137-3 : 2017 | Identical |
NEN EN ISO 11137-3 : 2017 | Identical |
DIN EN ISO 11137-3:2015-08 (Draft) | Identical |
NS EN ISO 11137-3 : 2017 | Identical |
EN ISO 11137-3:2017 | Identical |
NBN EN ISO 11137-3 : 2006 | Identical |
UNE-EN ISO 11137-3:2007 | Identical |
ISO 11137-3:2017 | Identical |
I.S. EN ISO 11137-3:2017 | Identical |
UNI EN ISO 11137-3 : 2006 | Identical |
SN EN ISO 11137-3 : 2017 | Identical |
ISO/TS 13004:2013 | Sterilization of health care products — Radiation — Substantiation of selected sterilization dose: Method VDmaxSD |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO/ASTM 51401:2013 | Practice for use of a dichromate dosimetry system |
ISO/ASTM 51650:2013 | Practice for use of a cellulose triacetate dosimetry system |
ISO 11462-2:2010 | Guidelines for implementation of statistical process control (SPC) — Part 2: Catalogue of tools and techniques |
ISO/ASTM 51276:2012 | Practice for use of a polymethylmethacrylate dosimetry system |
ISO/ASTM 52303:2015 | Guide for absorbed-dose mapping in radiation processing facilities |
ISO/ASTM 51818:2013 | Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV |
ISO/ASTM 51261:2013 | Practice for calibration of routine dosimetry systems for radiation processing |
ISO 14253-1:2017 | Geometrical product specifications (GPS) — Inspection by measurement of workpieces and measuring equipment — Part 1: Decision rules for verifying conformity or nonconformity with specifications |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO/ASTM 51275:2013 | Practice for use of a radiochromic film dosimetry system |
ISO/ASTM 51608:2015 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV |
ASTM E 2232 : 2016 : REDLINE | Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications |
ISO/ASTM 52701:2013 | Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO/ASTM 51607:2013 | Practice for use of the alanine-EPR dosimetry system |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO/ASTM 51649:2015 | Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV |
ISO/ASTM 51707:2015 | Guide for estimation of measurement uncertainty in dosimetry for radiation processing |
ISO/ASTM 52628:2013 | Standard practice for dosimetry in radiation processing |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO/ASTM 51631:2013 | Practice for use of calorimetric dosimetry systems for electron beam dose measurements and dosimetery system calibrations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.