1 Scope
2 Normative references
3 Definitions
4 Instrumentation
5 Determination of in situ sound attenuation
6 Uncertainty
7 Information to be recorded
8 Information to be reported
Annex
A Bibliography

Defines methods for evaluation of the in situ sound attenuation performance of a removable screen, in- or out-of-doors. Based on an insertion loss measurement for carrying out either with shielding of the actual sound source(s) or by means of an artificial sound source.

Committee
EH/1/4
DevelopmentNote
Supersedes 94/506270 DC. (11/2005)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Current
Supersedes

This International Standard specifies methods for evaluating the in situ sound attenuation performance of a removable screen, either indoors or outdoors. This engineering grade method is based on an insertion loss measurement that can be carried out either with shielding of the actual sound source(s) or using an artificial sound source.

The sound attenuation performance achieved by such a screen, as evaluated by the present International Standard, depends on:

  • diffraction around the edges of the screen;

  • transmission through the components of the screen;

  • absorption of the panels of the screen, as well as in its surroundings;

  • the room in which the screen stands if indoors.

When a specific work station is to be shielded, the in situ sound attenuation value describes the effect of the screen. However, when a complete area is to be shielded, the performance of the screen will vary depending on the positions used for measurement. Therefore, it is recommended that the maximum and minimum values of sound attenuation are given. The sound attenuation performance is determined in terms of insertion loss.

When assessing the performance of a screen located indoors, the room geometry and reflections from walls, ceilings and room fittings will influence the performance. As a consequence, the comparison of screen performance can only be made if the test conditions are identical.

This International Standard is applicable to screens with height and length greater than 1,5m. However, it may also be used for smaller screens provided that the interested parties come to an agreement on this.

As environmental conditions can affect the measurements outdoors, it is recommended that measurements should be restricted to within 25m of the screen. However, measurements may also cover a greater distance provided that the interested parties come to an agreement on this.

Differences can occur between in situ test results. Therefore, comparison of the performance of different screens can be made only on the basis of data based on the same measurement method performed at the same location.

This International Standard applies to a complete screen only and not to individual components from which it is made. Sound insulation and sound absorption for screen components (such as panel elements, doors, windows) should be measured according to other relevant standards.

This International Standard is not applicable to open plan offices screens nor to outdoor barriers dealing with community noise. It is also not intended for qualification purposes.

ISO 11200:2014 Acoustics Noise emitted by machinery and equipment Guidelines for the use of basic standards for the determination of emission sound pressure levels at a work station and at other specified positions
ISO 3744:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane
ISO 11546-2:1995 Acoustics Determination of sound insulation performances of enclosures Part 2: Measurements in situ (for acceptance and verification purposes)
IEC 60942:2003 Electroacoustics - Sound calibrators
ISO 11957:1996 Acoustics — Determination of sound insulation performance of cabins — Laboratory and in situ measurements
ISO 140-3:1995 Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements
ISO 10053:1991 Acoustics Measurement of office screen sound attenuation under specific laboratory conditions
ISO 11690-2:1996 Acoustics Recommended practice for the design of low-noise workplaces containing machinery Part 2: Noise control measures
ISO 10847:1997 Acoustics — In-situ determination of insertion loss of outdoor noise barriers of all types
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV Sound level meters
IEC 60804:2000 Integrating-averaging sound level meters
ISO 3743-1:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for small movable sources in reverberant fields Part 1: Comparison method for a hard-walled test room

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.