BS EN ISO 5167-2:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Orifice plates
Hardcopy , PDF
07-07-2022
English
18-03-2003
Committee |
CPI/30/2
|
DevelopmentNote |
Supersedes 98/121140 DC Together with 2003 Version of BS EN ISO 5167-1, BS EN ISO 5167-3, and BS EN ISO 5167-4 supersedes the 1997 Version of BS EN ISO 5167-1. (03/2003)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit.
This part of ISO 5167 also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167-1.
This part of ISO 5167 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as “vena contracta” and pipe tappings have been used with orifice plates but are not covered by this part of ISO 5167. This part of ISO 5167 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.
Standards | Relationship |
ONORM EN ISO 5167-2 : 2003 | Identical |
NS EN ISO 5167-2 : 1ED 2003 | Identical |
SN EN ISO 5167-2 : 2003 | Identical |
UNI EN ISO 5167-2 : 2004 | Identical |
DIN EN ISO 5167-2:2004-01 | Identical |
NEN EN ISO 5167-2 : 2003 | Identical |
EN ISO 5167-2:2003 | Identical |
I.S. EN ISO 5167-2:2003 | Identical |
ISO 5167-2:2003 | Identical |
NBN EN ISO 5167-2 : 2003 | Identical |
UNE-EN ISO 5167-2:2003 | Identical |
NF EN ISO 5167-2 : 2003 | Identical |
BS 7965:2009 | Guide to the selection, installation, operation and calibration of diagonal path transit time ultrasonic flowmeters for industrial gas applications |
ISO/TR 5168:1998 | Measurement of fluid flow Evaluation of uncertainties |
ISO/TR 3313:1998 | Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments |
ISO/TR 9464:2008 | Guidelines for the use of ISO 5167:2003 |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.