• BS IEC 62003:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - REQUIREMENTS FOR ELECTROMAGNETIC COMPATIBILITY TESTING

    Available format(s):  Hardcopy, PDF

    Superseded date:  06-10-2020

    Language(s):  English

    Published date:  01-01-2009

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
      4.1 General
      4.2 Requirements for EMC immunity
          4.2.1 Degrees of severity of tests for EMC immunity
          4.2.2 Safety system equipment
    5 Test methods
      5.1 General
      5.2 Test results assessment
    6 Safety requirements
    Annex A (normative) - Functional quality criteria of nuclear
            I&C equipment under test for disturbance immunity
    Annex B (informative) - Quality characteristics defining the
            classification of electromagnetic environment
            severity in the locations where nuclear I&C
            equipment is to be installed
    Annex C (informative) - Guidance for tests and evaluation of
            conformance with the requirements for disturbance
            immunity of operating nuclear I&C equipment
    Annex D (informative) - Example form of test report for
            nuclear I&C equipment tests for disturbance
            immunity
    Annex E (informative) - Emissions testing guidelines
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for electromagnetic compatibility testing of instrumentation and control equipment supplied for use in systems important to safety at nuclear power plants.

    General Product Information - (Show below) - (Hide below)

    Committee NCE/8
    Development Note Supersedes 07/30165539 DC. (06/2009)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-4-10 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-10: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-6-4:2006+AMD1:2010 CSV ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC TR 61000-1-5:2004 Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    IEC 62310-2:2006 Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    EN 50091-2:1995/corrigendum Jan. 1998
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
    IEC 60255-22-5:2008 Measuring relays and protection equipment - Part 22-5: Electrical disturbance tests - Surge immunity test
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-6-6:2003 Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    IEC 61000-4-9 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - IMPULSE MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-4-28:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-28: Testing and measurement techniques - Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
    IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
    IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
    IEC 61000-4-14:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
    IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
    IEC TR 61000-2-8:2002 Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61000-2-13:2005 Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted
    IEC 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods
    IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    IEC 61000-4-16 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-16: TESTING AND MEASUREMENT TECHNIQUES - TEST FOR IMMUNITY TO CONDUCTED, COMMON MODE DISTURBANCES IN THE FREQUENCY RANGE 0 HZ TO 150 KHZ
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective