FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Test apparatus
5 TLP waveform parameters
6 Test requirements and procedures
7 Failure criteria
Annex A (informative) - TLP design guidelines
Describes a method for pulse testing to evaluate the voltage current response of the component under test and to consider protection design parameters for electro-static discharge (ESD) human body model (HBM).
Committee |
EPL/47
|
DevelopmentNote |
Supersedes 08/30195574 DC. (08/2011)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 62615:2010 defines a method for pulse testing to evaluate the voltage current response of the component under test and to consider protection design parameters for electro-static discharge (ESD) human body model (HBM). This technique is known as transmission line pulse (TLP) testing. This document establishes a methodology for both testing and reporting information associated with transmission line pulse (TLP) testing. The scope and focus of this document pertains to TLP testing techniques of semiconductor components. This document should not become alternative method of HBM test standard such as IEC 60749-26. The purpose of the document is to establish guidelines of TLP methods that allow the extraction of HBM ESD parameters on semiconductor devices. This document provides the standard measurement and procedure for the correct extraction of HBM ESD parameters by using TLP.
Standards | Relationship |
IEC 62615:2010 | Identical |
IEC 60749-28:2017 | Semiconductor devices - Mechanical and climatic test methods - Part 28: Electrostatic discharge (ESD) sensitivity testing - Charged device model (CDM) - device level |
IEC 60749-27:2006+AMD1:2012 CSV | Semiconductor devices - Mechanical and climatic test methods - Part27: Electrostatic discharge (ESD) sensitivity testing - Machine model (MM) |
IEC 60749-26:2013 | Semiconductor devices - Mechanical and climatic test methods - Part 26: Electrostatic discharge (ESD) sensitivity testing - Human body model (HBM) |