BS ISO 8769:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Reference sources. Calibration of surface contamination monitors. Alpha-, beta- and photon emitters
Hardcopy , PDF
31-01-2016
English
30-09-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Traceability of reference sources
5 Specification of standard sources
6 Reference transfer instruments
Annex A (normative) - Particular considerations for
reference sources emitting electrons of energy
less than 0,15 MeV and photons of energy less
than 1,5 MeV
Bibliography
Defines the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors.
Committee |
NCE/2
|
DevelopmentNote |
Supersedes 09/30125465 DC. (09/2010) Supersedes 14/30283703 DC. (04/2016)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 8769:2016 | Identical |
ISO 8769:2010 | Identical |
ISO 7503-2:2016 | Measurement of radioactivity - Measurement and evaluation of surface contamination Part 2: Test method using wipe-test samples |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 4037-4:2004 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields |
IEC 62363:2008 | Radiation protection instrumentation - Portable photon contamination meters and monitors |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 7503-1:2016 | Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles |
IEC 60325:2002 | Radiation protection instrumentation - Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors |
ISO 12749-2:2013 | Nuclear energy, nuclear technologies, and radiological protection — Vocabulary — Part 2: Radiological protection |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
ISO 7503-3:2016 | Measurement of radioactivity Measurement and evaluation of surface contamination Part 3: Apparatus calibration |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.