Preface
1 Scope
2 Reference publications
3 Units of measure
4 Definitions
5 Symbols and abbreviations
6 Construction requirements
7 Test requirements
8 Sampling requirements
9 Test methods
10 Marking, labeling, and packaging
Annex A - Informative references
Annex B - Flammability test (material V-2 and VTM-2)
Annex C - Example of stability factor calculation
Annex D - Example of applying 8.2.2 and 8.2.3
Annex E - Example of applying 9.3.4.4
Annex F - Marking Locations Guide

This Standard applies to single-polarity, hand-, or tool-applied splicing wire and cable connectors intended for use with all alloys of copper, aluminum conductors, or copper-clad aluminum conductors, or all three, in accordance with the Canadian Electrical Code Part I, C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: Note: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, NFPA 70.

DevelopmentNote
Also numbered as NMX-J-548-ANCE & UL 486C. (10/2004) CORRECTED VERSION IS NOW AVAILABLE FOR THIS STANDARD. This version is revised in MAY 2021
DocumentType
Standard
ISBN
978-1-4883-1151-2
Pages
0
ProductNote
CORRECTED VERSION IS NOW AVAILABLE FOR THIS STANDARD. This version is revised in MAY 2021
PublisherName
Canadian Standards Association
Status
Current
Supersedes

Preface This is the harmonized ANCE, CSA Group, and UL standard for Splicing Wire Connectors . It is the fourth edition of NMX-J-548-ANCE, the fourth edition of CSA C22.2 No. 188, and the seventh edition of UL 486C. This harmonized standard has been jointly revised on May 5, 2021. For this purpose, CSA Group and UL are issuing revision pages dated May 5, 2021, and ANCE is issuing a new edition dated May 5, 2021. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to single-polarity, hand-, or tool-applied splicing wire and cable connectors intended for use with all alloys of copper, aluminum conductors, or copper-clad aluminum conductors, or all three, in accordance with the Canadian Electrical Code Part I, C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: Note: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, NFPA 70. a) Connectors intended to hold two or more conductor(s); b) Connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) Connectors intended for use with 6 AWG (13.3 mm2) or smaller conductors; d) Uninsulated connectors that are used in circuits rated 8 000 V and less; and e) Connectors intended for use in air-handling spaces. Note: Examples of splicing wire connectors include twist-on connectors, insulation-piercing or displacement connectors, spring-action connectors, tool-applied crimp, mechanical set-screw connectors, etc. 1.2 This Standard is intended for splicing wire connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; 2) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded, Class B concentric, compressed, and compact; and 3) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded single input wire (SIW). In Mexico, the use of aluminum conductors is permitted only with thermoset insulation and for sizes of 6 AWG (13.3 mm2) and higher. b) Copper-clad aluminum: 1) In Canada, this construction is not allowed. 2) In Mexico, this construction is not allowed. 3) In the United States: i) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and ii) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded, Class B concentric, compressed, and Class C concentric. c) Copper: 1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and 2) 30 AWG (0.05 mm2) to 6 AWG (13.3 mm2) stranded, Class B concentric and compressed, and Class C concentric. d) Compact-stranded copper conductors: In Canada and Mexico, for 8 AWG (8.4 mm2) and 6 AWG (13.3 mm2). In the United States this is not applicable. e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes. Note: For example, a connector rated for 6 AWG (13.3 mm2) – 14 AWG (2.1 mm2) may be additionally rated for 10 – 2.5 mm2. f) Other class and strand configurations as indicated by marking. 1.3 These requirements cover splicing wire connectors intended for: a) Copper-to-copper; b) Aluminum-to-aluminum; c) Copper-clad aluminum-to-copper-clad aluminum; d) Copper-to-aluminum or copper-clad aluminum and aluminum-to-copper-clad aluminum conductor combinations intended for intermixing of conductors and dry locations only; or e) All of the above. 1.4 This Standard is intended for splicing wire connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 °C or 90 °C, in accordance with the rating of the connector. 1.5 For products intended for use in Canada, general requirements are given in CAN/CSA-C22.2 No. 0. 1.6 This Standard does not apply to: a) Insulated splicing wire connectors intended for use at voltage levels in excess of 2 000; b) Terminal wire connectors; c) Wire binding screw terminals; d) Built-in terminal connectors on devices rated less than 30 A and intended for outlet box mounting or having provision for stress relief; e) Built-in terminal connectors on devices having integral cable clamps; f) Flat quick connect terminals; and g) Soldering lugs.

CSA C22.2 No. 38 : 2014 THERMOSET-INSULATED WIRES AND CABLES
IEC 60228:2004 Conductors of insulated cables
ASTM B 154 : 2016 : REDLINE Standard Test Method for Mercurous Nitrate Test for Copper Alloys
ASTM B 174 : 2017 : REDLINE Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors
ASTM D 5374 : 2013 : REDLINE Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
NFPA 90A : 2018 INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS
ASTM D 5207 : 2014 : REDLINE Standard Practice for Confirmation of 20–mm (50–W) and 125–mm (500–W) Test Flames for Small-Scale Burning Tests on Plastic Materials
ASTM B 172 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors
ASTM B 231/B231M : 2016 : REDLINE Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B 496 : 2016 : REDLINE Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
C22.2 NO. 75-17 Thermoplastic insulated wires and cables (Trinational standard with UL 83 and NMX-J-010-ANCE-2017)
ASTM B 173 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors
ASTM D 5423 : 2014 Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation