• There are no items in your cart

CAN/CSA-C22.2 NO. 60947-7-1:17

Current

Current

The latest, up-to-date edition.

Low-voltage switchgear and controlgear ? Part 7-1: Ancillary equipment ? Terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-1-ANCE and UL 60947-7-1)

Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2017

€242.28
Excluding VAT

Preface
NATIONAL DIFFERENCES
FOREWORD
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) - Clearances and creepage distances
Annex B (informative) - Items subject to agreement between
        manufacturer and user
Annex C (normative) - Tightening torques for the verification
        of the mechanical strength of screw-type clamping units
Annex DVA (normative) - Aluminum Requirements
Annex DVB (normative) - Normative References
Bibliography

Defines requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors.

DevelopmentNote
Also numbered as NMX-J-538/7-1-ANCE and UL 60947-7-1. (02/2017)
DocumentType
Standard
ISBN
978-1-4883-0019-6
Pages
65
PublisherName
Canadian Standards Association
Status
Current

Preface This is the harmonized ANCE, CSA Group, and UL standard for Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors. It is the first edition of NMX-J-538/7-1-ANCE, the first edition of CAN/CSA-C22.2 No. 60947-7-1, and the fourth edition of UL 60947-7-1. This edition of UL 60947-7-1 supersedes the previous edition (s) published on May 6, 2011.? This harmonized standard is based on IEC Publication 60947-7-1: Edition 2 (2002), Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors, as revised by corrigendum (March 2003). IEC 60947-7-1 is copyrighted by the IEC.? Scope This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to connect round copper conductors, with or without special preparation, having a cross-section between 0,2 mm2 and 300 mm2 (AWG 24/600 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V a.c. up to 1 000 Hz or 1 500 V d.c.? NOTE AWG is the abbreviation of \"American Wire Gage\" (Gage (US) = Gauge (UK))? kcmil = 1000 cmil;? 1 cmil = 1 circular mil = surface of a circle having a diameter of 1 mil? 1 mil = 1/1000 inch? This Standard may be used as a guide for? - terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.;? - terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc.;? - special types of terminal blocks, for example disconnect terminal blocks, etc.? Where applicable in this standard, the term \"clamping unit\" has been used instead of the term \"terminal\". This is taken into account in case of reference to IEC 60947-1.? 1.1DV D2 Modification to add the following:? 1.1DV.1 This Standard specifies requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support, in accordance with Annex DVB, National Electrical Code, NFPA 70 (for use in the USA), or CSA C22.1-15 Canadian Electrical Code, Part I (for use in Canada), and NOM-001-SEDE, Electrical Installations (Utility) ([for use in Mexico]).? 1.1DV.2 The wire range for terminal blocks covered by this standard include 0,051 mm2 to 1 010 mm2 (30 AWG to 2 000 kcmil) copper conductors and 3,31 mm2 to 1 010 mm2 (12 AWG to 2 000 kcmil) aluminum conductors. See Annex DVA for aluminum requirements.? In Mexico, 3,31 mm2 (12 AWG), 5,26 mm2 (10 AWG), and 8,37 mm2 (8 AWG) aluminum conductors are not allowed.? 1.1DV.3 The voltage range includes up to 1 500 Vac and 1 500 Vdc.

UL 60947-7-2:4ED 2017-01-27 Low-Voltage Switchgear and Controlgear - Part 7-2: Ancillary Equipment - Protective Conductor Terminal Blocks for Copper Conductors
UL 60947-7-3:3ED 2017-01-27 Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks
CAN/CSA-C22.2 NO. 60947-7-2:17 Low-voltage switchgear and controlgear ? Part 7-2: Ancillary equipment ? Protective conductor terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-2-ANCE and UL 60947-7-2)
CAN/CSA-C22.2 NO. 60947-7-3:17 Low-voltage switchgear and controlgear ? Part 7-3: Ancillary equipment ? Safety requirements for fuse terminal blocks (Trinational standard NMX-J-538/7-3-ANCE with UL 60947-7-3)

IEC 60715:2017 Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of switchgear, controlgear and accessories
CSA C22.2 No. 65 : 2013 WIRE CONNECTORS
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
ISO 4046:1978 Paper, board, pulp and related terms — Vocabulary
UL 746A:6ED 2012-09-06 Polymeric Materials - Short Term Property Evaluations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.