CEI EN 60076-11 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
Hardcopy , PDF
03-09-2019
English - Italian
01-01-2006
FOREWORD
1. Scope
2. Normative references
3. Terms and definitions
4. Service conditions
5. Tappings
6. Connections
7. Ability to withstand short circuit
8. Rating
9. Rating plate
10. Identification according to cooling
method
11. Temperature-rise limits
12. Insulation levels
13. Climatic, environmental and fire
behavior classes
14. General requirements for tests
15. Measurement of winding resistance
(routine test)
16. Measurement of voltage ratio and
check of phase displacement (routine test)
17. Measurement of short-circuit impedance
and load loss (routine test)
18. Measurement of no-load loss and
current (routine test)
19. Separate-source AC withstand voltage
test (routine test)
20. Induced AC withstand voltage test
(routine test)
21. Lightning impulse test (type test)
22. Partial discharge measurement
(routine and special test)
23. Temperature-rise test (type test)
24. Measurement of sound level
(special test)
25. Short-circuit test (special test)
26. Environmental test (special test)
27. Climatic test (special test)
28. Fire behaviour test (special test)
29. Tolerances
30. Protection against direct contact
31. Degrees of protection provided by
enclosures
32. Earthing terminal
33. Information required with enquiry
and order
Annex A (informative) - Installation and
safety of dry-type transformers
Annex ZA (normative) - Normative references
to international publications with their
corresponding European publications
Describes the dry-type power transformers (including auto transformers) having values of highest voltage for equipment up to and including 36 kV and at least one winding operating at greater than 1,1 kV.
Committee |
CT 14
|
DevelopmentNote |
Classificazione CEI 14-32. (03/2006)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 60076-11:2004 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
CEI 42-3 : 2ED 1997 | |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
CEI 14-41 : 2011 | TAP-CHANGERS - PART 2: APPLICATION GUIDE |
CEI 14-43 : 2011 | GUIDE FOR THE APPLICATION, SPECIFICATION, AND TESTING OF PHASE-SHIFTING TRANSFORMERS |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
CEI 14-45 : 2012 | POWER TRANSFORMERS DETERMINATION OF SOUND LEVELS - APPLICATION GUIDE |
IEC 60076-1:2011 | Power transformers - Part 1: General |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 60905:1987 | Loading guide for dry-type power transformers |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
CEI 15-26 : 1ED 1997 | VALUTAZIONE E CLASSIFICAZIONE TERMICA DELL'ISOLAMENTO ELETTRICO |