CEI EN 61347-2-2 : 2012
Current
The latest, up-to-date edition.
LAMP CONTROLGEAR - PART 2-2: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC STEPDOWN CONVERTORS FOR FILAMENT LAMPS
Hardcopy , PDF
English - Italian
01-01-2012
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Transformer heating
16 Construction
17 Creepage distances and clearances
18 Screws, current-carrying parts and connections
19 Resistance to heat, fire and tracking
20 Resistance to corrosion
Annex A (normative) - Test to establish whether a conductive
part is a live part which may cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
lamp controlgear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the
heating tests of thermally protected lamp controlgear
Annex E (normative) - Use of constant S other than
4500 in tw tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Particular additional requirements
for SELV d.c. or a.c. supplied electronic step-down
convertors for filament lamps
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes the electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1000 V, at 50 Hz or 60 Hz and with rated output voltage <= 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps.
Committee |
CT 34
|
DevelopmentNote |
Classificazione CEI 34-93. (01/2002) Supersedes CEI EN 61046. (02/2003) To be read in conjunction with CEI EN 61347-1. (07/2005)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 61347-2-2:2011 | Identical |
EN 61347-2-2:2012 | Identical |
CEI 64-8/7 : 2012 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS |
IEC 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61558-2-16:2009/A1:2013 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013) |
EN 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-16:2009+AMD1:2013 CSV | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.