CEN/TS 1948-4:2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 4: Sampling and analysis of dioxin-like PCBs
11-03-2023
25-07-2007
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle of the measurement procedure
6 Device, materials and [13]C[12]-labelled standards
7 Safety measures
8 Measurement procedure
9 Method validation and quality control requirements
10 Quality control requirements for the measurement
11 Quality assurance criteria for
extraction/clean-up/quantification procedure blanks
12 Performance characteristics (informative)
13 Interferences (informative)
Annex A (informative) Toxicity and toxic equivalency
Annex B (informative) Example for clean-up of PCB and the
separation from PCDD/PCDFs
B.1 General
B.2 Method
Annex C (informative) Possible interferences in dioxin-like
PCB analysis
Annex D (informative) Measurement of the marker PCB 28, 52, 101,
138, 153, and 180 in addition to the
12 non- and mono-ortho-PCB
Bibliography
This document specifies sampling from stationary sources, extraction, clean-up, identification and quantification procedures of the dioxin-like PCBs. The procedure described lays down requirements to measure the PCB congeners given in Annex A (see Table A.1). It is applicable to the twelve non- and mono-ortho PCB designated by the WHO. It is optimised to measure PCB concentrations in the range of 0,01 ng WHO-TEQPCB/m3.In addition to the 12 non- and mono-ortho-PCB the present document is also applicable to measure further PCB-congeners like the so-called “marker PCB” 28, 52, 101, 138, 153, 180 (see Annex D).This document specifies a framework of quality control requirements which have to be fulfilled by any PCB sampling, extraction, clean-up, identification and quantification methods to be applied. It is assumed that due to their similar chemical behaviour PCBs may be sampled from stationary sources together with the PCDDs/PCDFs by the same methods. The complete sampling procedure is described in the EN 1948-1. Each of the three sampling methods of EN 1948-1 can be combined with the methods described in this document to complete the measurement procedure. EN 1948-1 is an integral part of the complete measurement procedure and is necessary for the determination of PCBs. In addition it is possible to measure PCBs together with PCDDs/PCDFs by applying EN 1948 Part 1, Part 2, Part 3 and CEN/TS 1948 Part 4.
Committee |
CEN/TC 264
|
DocumentType |
Technical Specification
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
UNI CEN/TS 1948-4 : 2007 | Identical |
UNE-CEN/TS 1948-4:2009 EX | Identical |
DD CEN/TS 1948-4:2007 | Identical |
NF CEN/TS 1948-4 : 2007 XP | Identical |
DIN CEN/TS 1948-4:2007-10 | Identical |
NEN NPR CEN/TS 1948-4 : 2007 | Identical |
S.R. CEN TS 1948-4:2007 | Identical |
ISO 16000-14:2009 | Indoor air — Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
BS ISO 16000-14:2009 | Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
DIN ISO 16000-14:2012-03 | Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009) |
ISO 4793:1980 | Laboratory sintered (fritted) filters — Porosity grading, classification and designation |
EN 1948-2:2006 | Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 2: Extraction and clean-up of PCDDs/PCDFs |
EN ISO 9169:2006 | Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006) |
EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
EN 1948-1:2006 | Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs |
EN 1948-3:2006 | Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 3: Identification and quantification of PCDDs/PCDFs |
ISO 9169:2006 | Air quality Definition and determination of performance characteristics of an automatic measuring system |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.