• CLC/TS 50131-2-7-3:2009

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active)

    Available format(s): 

    Withdrawn date:  10-03-2023

    Language(s): 

    Published date:  20-03-2009

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
      3.1 Terms and definitions
      3.2 Abbreviations
    4 Functional requirements
      4.1 Event processing
      4.2 Operational requirements
      4.3 Detection
      4.4 Immunity to false alarm sources
      4.5 Tamper security
      4.6 Electrical requirements
      4.7 Environmental classification and conditions
    5 Marking, identification and documentation
      5.1 Marking and/or identification
      5.2 Documentation
    6 Testing
      6.1 General test conditions
      6.2 Basic detection test
      6.3 Performance tests
      6.4 Switch-on delay, time interval between signals
           and indication of detection
      6.5 Fault condition signals or messages: self tests
      6.6 Tests of immunity to false alarm sources
      6.7 Tamper security
      6.8 Electrical tests
      6.9 Environmental classification and conditions
      6.10 Marking, identification and documentation
    Annex A (normative) - Catalogue of standard glass types
    Annex B (normative) - List of small tools suitable for
            testing immunity of casing to attack
    Annex C (normative) - Dimensions & requirements of a
            standard test magnet
      C.1 Normative references
      C.2 Requirements
    Annex D (normative) - Immunity test: Small objects
            hit sensitivity
    Annex E (normative) - Immunity test: Soft objects hit
            sensitivity
    Annex F (normative) - Immunity test: Hard objects hit
            sensitivity
    Annex G (normative) - Immunity test: Static pressure
            sensitivity
    Annex H (normative) - Immunity test: Dynamic pressure
            sensitivity
    Annex I (normative) - General testing matrix
    Annex J (normative) - Performance test setup
      J.1 Performance test setup
      J.2 Alternative performance test setup
    Annex K (normative) - Performance sensitivity test

    Abstract - (Show below) - (Hide below)

    This Technical Specification is for active surface mounted glass break detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors and uses environmental classes I to IV (see EN 50130 5). This Technical Specification does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 79
    Document Type Technical Specification
    Publisher European Committee for Standards - Electrical
    Status Withdrawn
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    TR 103 056 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    EN ISO 527-2:2012 Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:2012)
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN ISO 527-1:2012 Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:2012)
    ISO 527-2:2012 Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics
    ISO 2039-2:1987 Plastics Determination of hardness Part 2: Rockwell hardness
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
    EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN ISO 2039-2 : 1999 PLASTICS - DETERMINATION OF HARDNESS - PART 2 - ROCKWELL HARDNESS
    IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
    EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    ISO 527-1:2012 Plastics Determination of tensile properties Part 1: General principles
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective